26
USA
5958 931 01
Major advantages:
• Excellent food quality.
• Standardized procedure LTC guarantees repeatable results
year-in - year-out.
• Typical roast aroma, juiciness from centre to the rim.
• Uniform colour and perfected evenness in the degree of
doneness.
• Fast maturing process - time saving and use of fresh cut.
• Significant less cooking shrinkage, 5-8 % (depend on food
quality and selected core temperature).
• Remarkable gain of portions for selling.
• Dramatic energy-saving due to the intelligent EFS - LTC
program.
CLEANING SYSTEM (AIR-O-CLEAN)
This system executes an automatic oven chamber cleaning
procedure using suitable detergents according to the level of soil
detected; the program has four different cleaning cycles.
CLEAN 1 Soft (light)
For fresh soil deriving from low fat cooking (e.g. after a STEAM
cooking cycle)
CLEAN 2 Medium (normal)
If the oven chamber is only moderately soiled and after cooking
fatty foods.
CLEAN 3 Strong (intensive)
If the oven chamber is very dirty due to cooking of high fat foods
(e.g. roasted chicken, sausages).
CLEAN 4 X-Strong (super intensive)
For heavy grime resulting from very high fat foods (e.g. roasted
chicken, sausages) also with dry residues (baked-on food).
F00...---> F19... (recipes)
These are the 20 pre-stored recipes of the main international
dishes.
For further information see the relative recipe book.
Proceed as follows to use preset programs:
Note:
The CLEANING SYSTEM cycle
will commence
when the tem-
perature automatically reaches
70°C in the oven chamber
.
Before carrying out a CLEANING SYSTEM cycle make sure the
containers (located under the control panel) are supplied with
cleaning products of the required type: refer first to section 7.
CARE AND MAINTENANCE.
Warning:
If the detergent and/or rinse aid containers are empty or the
relative supply lines are empty, before starting the
CLEANING
SYSTEM
cycle a preparatory cycle must be executed. This
allows the supply pipes to fill with the required liquids and ensures
the subsequent cleaning cycle is performed correctly.
Note 2:
When setting a cooking cycle, press the
P
button twice and select
the menu item FIND BY NUMBER OR FIND BY NAME, or press
P
, holding it down for a few seconds to exit setting and proceed
as follows.
1) Press button
P,
program
A0
flashes
program
A O P r e H e a t S t e a m i n g
selected
P : M E N U
the message A0
P r e H e a t S t e a m i n g
appears on the
DISPLAY.
2) Select the desired program or go to step 3).
3) Press START/STOP to start the A0 PRE-HEAT... cycle.
To
exit
,
edit
,
skip phase
, see the paragraphs of the normal
programs.
4.4.7 DELETING A RECIPE OR PROGRAM FROM THE
MEMORY
1) Press button
I
to switch on the oven.
2) Press button
P
.
3) Select the recipe or the program to be deleted.
4) Press button
P
and select the CLEAR RECIPE option.
RECIPE NAME
0 1
C O O K I N G
P O T A T O E S
selected option
P : C L E A R
R E C I P E
5) Press button
P
to remove the recipe or program from the
memory.
RECIPE NAME
0 1
C O O K I N G
P O T A T O E S
selected option
P : C O N F I R M
6) Press button
P
again and hold it down for a few seconds to exit
the programs.
5. INFORMATION AND ERROR CODES
These codes may appear on the time display.
INFORMATION codes
Codes indicating a value, function, or state.
Cln
- CLEANING SYSTEM program switched on.
Clnt
- Semiautomatic cleaning program switched on.
cont -
Unlimited time setting.
cool -
Oven cooling on.
End -
End of a cycle or function.
FILL -
Boiler filling. (Ensure water supply tap/cock are open).
Hold -
Cooking option, HOLD function active.
LOAd
- Place the food in the oven.
oPEn -
Boiler discharge valve opening.
PrEH -
Boiler in preheating phase.
Soap
- Detergent. Spray a suitable product on the surfaces to be
cleaned as indicated in point 4) of the semiautomatic chamber
cleaning cycle (see par. 7. CARE AND MAINTENANCE).
StArt -
Press the START button to start the program.
Stby
- CLEANING SYSTEM cleaning standby time.
ERROR codes
Codes indicating the need to call technical service
EH2O -
Water supply pressure too low for CLEANING SYSTEM
(pressure requirements from 1.5 to 2.5 bar)
EFUN -
Fan automatic reset thermal switch device. UP appears
on the small DISPLAY with reference to the single fan (6-10
GN) or upper fan (20 GN) of the chamber and DO in reference
to the lower fan (only 20 GN).
Содержание 260085
Страница 8: ...8 5958 931 01 NO TEXT ON THIS PAGE ...
Страница 30: ...30 USA 5958 931 01 NO TEXT ON THIS PAGE ...
Страница 52: ...52 IT 5958 931 01 NOTEXT ONTHIS PAGE ...
Страница 74: ...74 5958 931 01 CDN NOTEXT ONTHIS PAGE ...
Страница 96: ...96 5958 931 01 ES NOTEXT ONTHIS PAGE ...
Страница 97: ...97 5958 931 01 HU TS TM PRB ...