10.8.1.6 COOL DOWN stage
Quick cool down
If you answer 1 (yes) :
The machine will fill with cold water to a fixed higher level. The machine does not monitor
the drop in temperature of the wash water. This function is used mainly for reducing the
temperature of the water before it is discharged.
Do not use this function to prevent creasing of the wash load.
If you answer 0 (no) :
The machine makes a controlled cool down as described earlier.
Motor action
Allows you to determine drum action during cool-down (1 = slow, 2 = normal).
Valve opening time
98 °C to 70 °C
You program the length of time during which the cold water valve opens every 30 seconds,
but the machine monitors constantly to ensure that the cool-down rate does not exceed the
limit value, which is 4 ° C/minute when the machine is delivered. If the limit value is ex-
ceeded, no water will be added until the mean value is acceptable again (from 1 to 30
seconds).
Valve opening time
70 °C to End
You program the length of time during which the cold water valve opens every 30 seconds.
The rate of cooldown is not monitored during this stage. The valve opens and closes de-
pending on the programming mode (from 1 to 30 seconds).
Final Temperature
Enter the temperature you require for the water at the end of cool-down (from 1 to 90 °C).
Drum Speed
You can determine the drum speed during cool-down (from 10 to 50 rpm).
Drum Acceleration
This function allows you to determine the rate of acceleration for the drum, i.e. the rpm per
second at which its speed should increase until it reaches the speed you set in the last
function (from 2 to 10 rpm/mn).
Select the wished function by pressing this
�
or
�
keys.
Decrease or increase the value by pressing this (-) or (+) keys.
Then valid with
�
key.
10.8.1.7 DRAIN stage
Pause before drain
If you answer 1 = pause : The washer extractor will stop and the buzzer will sound before
the drain opens.
If you answer 0 = normal : The program module starts, with no pause.
Motor action
Allows you to determine drum action during drain (1 = slow, 2 = normal).
Normal drain
The drain will be open. The motor may be at a standstill, on gentle action. During this time
the drum water will be discharged (1 = selected).
Optional drain
Actually out of service (2 = A ;4 = B ;8 = C ;16 = D).
Drain time
Here you can determine the drain time (from 0 to 250 seconds).
Distribution time
Here you can determine the length of time the drum operates at distribution speed (from 0
to 250 seconds).
Drum speed
Here you can determine the drum action during the time programmed for the drain cycle
(from 10 to 50 rpm).
Drum acceleration
This function allows you to determine the rate of acceleration for the drum, i.e. the rpm per
second at which its speed should increase until it reaches the speed you set in the last
function (from 2 to 10 rpm/mn).
Select the wished function by pressing this
�
or
�
keys.
Decrease or increase the value by pressing this (-) or (+) keys.