Installation manual
7.4
Electrical connections
QuickDry QDC
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heating
220–230V 1 ~
50/60
3.1
3.3
16
240V 1 ~
50/60
3.2
3.5
16
220–230V 3 ~
50/60
3.1
3.3
16
240V 3 ~
50/60
3.2
3.5
16
220–230V 3 ~
50/60
4.9
5.1
16
240V 3 ~
50/60
5.1
5.4
16
380–400V 3 ~
50/60
4.9
5.1
10
415V 3 ~
50/60
5.1
5.3
10
440V 3 ~
60
5.1
5.4
10
480V 3 ~
60
5.1
5.3
10
QuickDry QDC Condense
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heating
380–400V 3 ~
50/60
1.9
2.2
10
440V 3 ~
60
2.0
2.4
10
440V 3 ~
60
3.0
3.4
10
100V 1N ~
50/60
1.2
1.5
15
7.5
Option
7.5.1
External connection 100 mA
A special connection terminal is located on the connection console.
This connection can be used as external control of a fan.
The terminal for external control is equipped with 220–240V max.100 mA and is intended solely for the operation of a
contactor.
Max. connection 100 mA.
Gnd. must not be used for earthing of external board.
X1
X2 Gnd.
fig.7154