8.4
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220–240V 1 ~
50/60
6.0/8.0
6.3/8.3
35/50
220–230V 3 ~
50/60
6.0/8.0
6.3/8.3
20/25
240V 3 ~
50/60
6.0/8.0
6.3/8.3
16/25
380–415V 3 ~
50/60
6.0/8.0
6.3/8.3
10/16
440/480V 3 ~
60
6.0/8.0
6.3/8.3
10/16
230V 1N ~
50
6.0/8.0
6.3/8.3
35/50
400V 3N ~
50
6.0/8.0
6.3/8.3
10/16
8.5
Option
External connection
A special connection terminal is located on the motor bracket.
This connection can be used as external control of a fan.
The terminal for external control is equipped with 110V max.100 mA and is intended solely for the operation of a
contactor.
Max. connection 100 mA.
Gnd. must not be used for earthing of external board.
X1
X2 Gnd.
fig.7154