User manual
19
9.8
Cleaning the inlet hoses and the valve filters
Clean regularly both (for hot and for cold water) inlet hoses and both valve filters.
1.
1
45°
20°
2
3
2.
3.
4.
fig.W01592
Emergency drain
Because of a malfunction, the appliance cannot drain the water.
If this occurs, do steps (1) through (8) of
. If necessary, clean the pump.
9.9
Frost precautions
If the appliance is installed in an area where the temperature can be less than 0
℃
, remove the remaining water from
the inlet hose and the drain pump.
1. Disconnect the mains plug from the mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a container and let the water flow out of the hose.
4. Empty the drain pump. Refer to the emergency drain procedure.
5. When the drain pump is empty, install the inlet hose again.
Warning
Make sure that the temperature is more than 0
℃
before you use the appliance again.
The manufacturer is not responsible for damages caused by low temperatures.