Installation manual
13
Three-phase connection 3 AC + E (PE)
Connect the machine’s power cable to the terminal block on the printed circuit provided for the purpose.
L1
L2
L3
PE
F1
Phase no 1
Phase no 2
Phase no 3
Earth connection
Control fuse to protect the electrical control
circuit (1.25 A)
Single-phase connection 1N AC + E (PE)
Connect the machine’s power cable to the terminal block on the printed circuit provided for the purpose.
L1
N
PE
F1
Phase no 1
Neutral
Earth connection
Control fuse to protect the electrical control
circuit (1.25 A)
Single-phase connection 1 AC + E (PE)
Connect the machine’s power cable to the terminal block on the printed circuit provided for the purpose.
L1
L2
PE
F1
Phase no 1
Phase no 2
Earth connection
Control fuse to protect the electrical control
circuit (1.25 A)