Electrolux Professional IB42310 Скачать руководство пользователя страница 1

Installation manual

Ironers

IB42310 – IB42314 – IB42316

Originals instructions

05405004/EN

Содержание IB42310

Страница 1: ...Installation manual Ironers IB42310 IB42314 IB42316 Originals instructions 05405004 EN ...

Страница 2: ......

Страница 3: ... Check before use 15 11 Disconnecting the machine 17 12 Releasing process to follow in case of connection while the bed is in back position 17 13 Safety thermostat s adjustment 18 14 Star Triangle Commutation diagram 19 15 Annexes 20 15 1 Control diagram printed circuit 20 15 2 Component implantation printed circuit 21 16 Conversion of measurement units 22 The manufacturer reserves the right to ma...

Страница 4: ......

Страница 5: ...y volume below 1100 litres can for ward these to the local collection and treatment department If exceeding this volume the owners of packing waste will ensure their valuation by reuse recycling or any other action aiming at producing reusable materials or energy or provide them contractually to a certified intermediate authorised to transport trade or broke waste Therefore these texts forbid land...

Страница 6: ...monic is permissible Voltage unbalance Neither the voltage of the negative sequence component nor the voltage of the zero sequence component in three phase supplies shall exceed 2 of the positive sequence component Voltage interruption Supply interrupted or at zero voltage for not more than 3 ms at any random time in the supply cycle There shall be more than 1 second between successive interruptio...

Страница 7: ...ation manual 7 5 Technical characteristics Neither base nor sealing are indispensable It is yet possible to fix the ironer to the floor To do so use the holes made to block the machine on the transport pallet ...

Страница 8: ...0 60 E Power supply cable mm see table see table see table Electric power total load kW 5 20 7 50 8 70 Electric heating power kW 5 00 7 20 8 40 Max hourly consumption kWh h 4 28 5 82 7 27 Max water evaporation capacity1 l h 5 00 6 78 8 05 Heat loss W 150 225 260 F Control fuse 250 V A 1 25 1 25 1 25 Movement motor power kW 0 18 0 18 0 18 Fan motor power kW nothing 0 06 0 06 Ironing speed at 50 60 ...

Страница 9: ...0 A 4 x 2 5 mm 16 A 1 4 m 230 240 V 3 E 50 60 Hz 18 5 A 3 x 25 A 4 x 2 5 mm 25 A 1 4 m 200 208 V 3 E 50 60 Hz 21 3 A 3 x 25 A 4 x 2 5 mm 25 A 1 4 m 440 460 V 3 E 50 60 Hz 9 7 A 3 x 20 A 4 x 2 5 mm 16 A 1 4 m 230 V mono 2 E 50 60 Hz 33 6 A 3 x 40 A 3 x 6 mm 50 A Ironing width Supply voltage Rated intensity Main switch Connection cable section Fuse 1 6 m 400 415 V 3 N E 50 60 Hz 12 5 A 4 x 20 A 5 x ...

Страница 10: ...he open air by the shortest way and with as few bents as possible Incline the flexi hose downwards as compared to the machine Protect the end of the exhaust duct from the bad weather Do not connect the exhaust duct to a gas coal fuel oil furnaces chimney Separate it also from any other ducting tumble dryer finishing cabinet 7 Installation The ironer must be transported to its final position in the...

Страница 11: ...m of 10 cm between the machine and any rear wall 3 Install the four adjustable feet and counternuts delivered with the machine as shown on the Fig 3 below Place the machine on a perfectly stable and level floor Check the horizontality of the machine using a spirit level at both its centre and ends If required use the adjustable feet to level the machine then lock with counternuts Control the floor...

Страница 12: ... of your installation is sufficient before con necting the machine Use only a cable to supply the machine Connect the machine to a four pole switch and protective fuses customer supply The opening distance of the four pole switch contact should be 3 mm minimum The values of these apparatus are indicated in chapter Technical characteristics Install the main switch in an easily accessible position I...

Страница 13: ...e phase connection 1N AC E PE Connect the machine s power cable to the terminal block on the printed circuit provided for the purpose L1 N PE F1 Phase no 1 Neutral Earth connection Control fuse to protect the electrical control circuit 1 25 A Single phase connection 1 AC E PE Connect the machine s power cable to the terminal block on the printed circuit provided for the purpose L1 L2 PE F1 Phase n...

Страница 14: ... 400 volts do not touch the transformer connection which should be as indicated in the margin If the voltage is 400 volts example 420 230 volts connect threads to the transformer as indicated in the margin Note The latter solution is advised even it the voltage is normally equal to 400 Volts but may be subject to time variations your machine electrical equipment will not be overfeed If the voltage...

Страница 15: ...otates clockwise see from the machine right side but the safety hand device is inoperative You must not in any case continue to operate the ironer Stop the machine and invert the phases 10Check before use The ironing machine is delivered with the bed in contact with the cylinder 1 Check that the machine s On Off switch is to 0 2 Turn on the main switch of the machine 3 Push on the On Off button th...

Страница 16: ...ses and bed closed D Inverted phases and bed opened When starting up the ironer the bed remains closed the cylinder ro tates in the right way but the hand safety device is inoperative Do not use the machine Modify the phases order see below When starting up the ironer the cylinder rotate in the wrong way and the bed blocks in rear position Release the bed and modify the phases order see below and ...

Страница 17: ...rative to check the order of connection of the phases before starting the ironer see previous page 12Releasing process to follow in case of connection while the bed is in back position If you connect the machine with the bed in back position and the control pedal activated when two wires of phases are inverted an electrical device doubled with a mechanical system of locking prevents to deteriorate...

Страница 18: ...This safety thermostat is adjusted in our plant so that the regulation thermostat doesn t go above the temperature corresponding to the position which is approximately 150 C even when it is set on a higher temperature If you want to increase the ironing temperature disman tle the bed s back casing and turn the rod T of the safety thermostat This way you can limit the maximum ironing tempera ture a...

Страница 19: ... ensure that all burner system components function correctly 14Star Triangle Commutation diagram A Heating resistor commutation B Motion motor commutation Star commutation from 380 to 460 volt three phases Triangle commutation from 200 to 240 volt three phases P1 Commutation from 200 to 240 volt mono phase C1 Phase shifting capacitor ...

Страница 20: ...20 Installation manual 15Annexes 15 1 Control diagram printed circuit ...

Страница 21: ...Installation manual 21 15 2 Component implantation printed circuit PLASTRON PANEL CONTROL BARRE BAR CUV BED MONNAYEUR COIN OPERATING SYSTEM MOTEUR MOTOR CHAUFFAGE HEATING VENT VENTILATEUR PEDALE PEDAL ...

Страница 22: ...in gallon U S A 1 gal 3 785 33 dm or l 1 gal 231 cu in horse power 1 HP 0 745 7 kW 1 HP 1 013 9 ch inch 1 in 25 4 mm joule 1 J 0 000 277 8 Wh 1 J 0 238 92 cal kilogramme 1 kg 2 205 62 lb kg cm 1 kg cm 98 066 5 Pa 1 kg cm 0 980 665 bar 1 kg cm 10 000 mm H2O 1 kg cm 735 557 6 mm Hg pound 1 lb 453 592 37 g meter 1 m 1 093 61 yd 1 m 3 280 83 ft 1 m 39 37 in cubic meter 1 m 1 000 dm 1 m 35 214 7 cu ft ...