20
User manual
Check that the filter is clean and unbroken. Clean or replace if necessary.
fig.7239
Remove any lint and dust around the machine.
7.4
Machines with residual moisture control (RMC)
At regular basis, wipe off/clean drum and lifters with citric acid (Acidum citricum). If soap/softener residue remains, it
is recommended also to use a coarse sponge.
Lack of cleaning can affect the functionality of the residual moisture control. This can result in more moist load than
requested at program end.
7.5
Maintenance to be carried out by qualified service personnel
Contact qualified service personnel to perform the following maintenance:
After 1600 hours of operation or once a year, whichever comes first:
• Clean the fan, the exhaust duct and the fresh-air intake to the room
• On machines with RMC: Clean the glide surface on the RMC graphite collector
• Clean the area around the drum
• Clean the motors
• Check the belt tension
Содержание Compass Pro TD6-37
Страница 1: ...User manual Tumble dryer TD6 37 Compass Pro Type N2 Original instructions 438917958 EN 2022 10 04 ...
Страница 2: ......
Страница 4: ......
Страница 22: ......
Страница 23: ......
Страница 24: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...