Installation manual
17
4.4
Drain connection (only for machines with heat pump)
Connect the drain to the heat pump unit.
Note!
The outlet condense water (4) and the cooling water (5) must be connected to separate outlets.
The hose (4) must be positioned over the water level in the floor drain.
Note!
The drain must be lower than the drain outlet from the heat pump unit. If not the water will flow back into the
machine. Adjust with the feet.
The hoses shall hang in gentle arcs.
4
5
fig.W00609
4.5
Water connection (only for machines with heat pump)
All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal-
lation and servicing.
Water pipes and hoses should be flushed clean before installation.
The machine shall be connected with new water hoses. Re-used water hoses must not be used.
Hoses are to be of an approved type and grade and comply with IEC 61770.
After installation hoses must hang in gentle arcs.
All connectors present on the machine must be connected.
Connect the water to the water cooling system (6).
6
W00609A
Water pressure:
Miniumum: 50 kPa (0.5 kp/cm
2
)
Maximum: 800 kPa (8 kp/cm
2
)
Recommended: 200–600 kPa (2–6 kp/cm
2
)
Note!
If the water pressure is below the minimum value, the drying result can not be guaranteed for certain
program.