Table 3. Holding Registers (2 x 16 bit)
Sensor Data
Register Address
No.
Reg.
Values
Type
Float 1 (Top
Float)
45001
5000
2
Read
Only
Total Fluid Level in Tank
Floating point upper two bytes
(v3.14 and higher)
45002
5001
Read
Only
Total Fluid Level in Tank
Floating point lower two bytes
(v3.14 and higher)
Float 2 (Bottom
Float)
45003
5002
2
Read
Only
Water Interface Level in Tank
Floating point upper two bytes
(v3.14 and higher)
45004
5003
Read
Only
Water Interface Level in Tank
Floating point lower two bytes
(v3.14 and higher)
Oil Level in
Tank (top to
bottom)
45005
5004
2
Read
Only
Oil Level in Tank(top-bottom)
Floating point upper two bytes
(v3.14 and higher)
45006
5005
Read
Only
Oil Level in Tank(top-bottom)
Floating point lower two bytes
(v3.14 and higher)
Total Volume
(top level x K
45007
5006
2
Read
Only
Total Volume(top level x K factor)
Floating point upper two bytes
Содержание DLS 2100 Series