Assemble Lateral Shift
1. Install the four threaded studs into the four T-slot nuts.
2. Insert two T-slot nut assemblies into each of the lateral shift extrusions (Figure 1).
3. Insert one self-tapping screw into each end of the extrusions to trap T-slot nut assemblies in the tracks (Figure 1).
4. Connect lateral shift extrusions to the plasma static wall mount by inserting the T-slot studs into holes and secure using four flat
washers, four lock washers, and four hex nuts (Figure 2).
Mount Lateral Shift
READ INSTALLATION INSTRUCTIONS COMPLETELY BEFORE PROCEEDING
1. Attach latching flags to mount using the 10-24 Phillips head screws, Nylon washers, and Nylock nuts
(see Figure 2). Tighten until friction will hold the flags in place.
2. Attach mounting buttons to plasma using four M8 x 25 cap screws provided (see Figure 3 & Figure 4).
INSTALLATION INSTRUCTIONS
READ COMPLETELY BEFORE PROCEEDING
Figure 1
Figure 2
T-SLOT NUT ASSEMBLIES
SELF TAPPING
SCREW
SELF TAPPING
SCREW
Figure 2
Figure 3
Figure 4