4-4
Applying Power for the First Time
P/N 0013-1027-005 Rev A
9. Select the appropriate motor model from the Motor Type list box. Verify the Encoder
selection is correct. The last letter of the Motor Type defines the encoder resolution
(encoder lines per revolution).
10. Click the Update PM button to initialize the Personality Module. The Percent Complete
indicator displays the status of the initialization.
• When the Percent Complete indicator reaches 100% the PM is initialized, choose the
Close button to exit the Initialize PM dialog box.
• If you get an “IQ not responding” error message, follow the instructions below.
(1) Click the Close button to exit the Initialize PM dialog box.
(2) Select PC Setup from the Communications menu and check your communica-
tions setup. You should first verify that the communications port that you have
selected is the one that your cable is connected to. Then verify that the commu-
nications protocol matches the protocol in the IQ. If this is not a new IQ, any of
these setting may have been changed by the previous user. “Serial Ports” on
page 3-18 lists the settings for a new IQ.
(3) Verify that the serial cable is constructed properly. Refer to “Serial Ports” on
(4) If you have selected an address on the address dip switches, verify that the
same address is selected in the Communications menu, Axis Select dialog box.
11. Select Initialize PM from the File menu and continue with Step 7 above. Make sure that
the motor is not connected to the load when applying power to prevent any mechanical
damage in case of a fault. Ensure the PDM is disabled (turn the Enable input off, or
select Disable from the Run menu of IQ Master after power is applied). Apply input
power and check the LEDs. The green PSM READY LED should turn on and the bicolor
STATUS LED should turn green. If the STATUS LED is red rather than green, the PDM
is in a fault condition. Select Status from the Monitor menu to find out the type of fault.
Correct the fault (the STATUS LED will turn green when the fault has been cleared and
a reset or hard reset performed). Check that air is coming out of the top of the PDM to
ensure that the fan is operating. The green PSM READY LED should turn on and
remain on.
12. Ensure that the PDM is disabled. Select Encoder from the Diagnostics menu. Verify that
the Counts value increases positively when the motor shaft is rotated clockwise as
viewed facing the motor shaft.
13. Enable the PDM, using the Enable input or Enable from the Run menu. Verify that the
motor is stationary and that it has holding torque.
F
IGURE
4.2
Initialize PM Dialog Box for IQ-5000
Initialize Personality Module
IQ Series
Drive Type
Motor Type
Motor
Encoder Size
Lines/rev
H-3007-N-H
2000
Update PM
Close
PDM-10
Percent complete: 0%
IQ 550
Factory Default Initialization
Содержание IQ 2000
Страница 8: ...Intro 6 Contents P N 0013 1027 005 Rev A ...
Страница 48: ...2 30 Installation P N 0013 1027 005 Rev A FIGURE 2 23 IQ 5000 Transformer Load Regulation Curve ...
Страница 49: ...Installation 2 31 IQ 2000 5000 Installation Manual FIGURE 2 24 PSM AUX Outline and Connection Diagram ...
Страница 51: ...Installation 2 33 IQ 2000 5000 Installation Manual FIGURE 2 26 IQ 2000 Transformer Load Regulation Curve ...
Страница 53: ...Installation 2 35 IQ 2000 5000 Installation Manual FIGURE 2 29 24V Sourcing I O Conversion Card ...
Страница 54: ...2 36 Installation P N 0013 1027 005 Rev A ...
Страница 79: ...Wiring 3 25 IQ 2000 5000 Installation Manual 3Wiring FIGURE 3 25 IQ 5000 Power Wiring ...
Страница 80: ...3 26 Wiring P N 0013 1027 005 Rev A FIGURE 3 26 PSM AUX Connections ...
Страница 81: ...Wiring 3 27 IQ 2000 5000 Installation Manual FIGURE 3 27 IQ 2000 Power Wiring for PDM 10 20 and 30 ...
Страница 82: ...3 28 Wiring P N 0013 1027 005 Rev A FIGURE 3 28 IQ 2000 Power Wiring for PDM 75 ...
Страница 88: ...3 34 Wiring P N 0013 1027 005 Rev A ...
Страница 94: ...4 6 Applying Power for the First Time P N 0013 1027 005 Rev A ...
Страница 104: ...6 4 Specifications P N 0013 1027 005 Rev A ...
Страница 114: ...Help 6 EU Directives P N 0013 1027 005 Rev A ...