PROFESSIONAL POWER AMPLIFIER

Owner‘s Manual    5

1  Introduction

1.1 Welcome

Thank you for choosing Electro-Voice Q series amplifier. Please take time to consult this manual so that you can understand
all the features built into your Electro-Voice amplifier and fully utilize all its performance capabilities.

1.2 Unpacking and Inspection

Carefully open the packaging and take out the power amplifier. Inspect the power amp’s enclosure for damages that might
have happened during transportation. Each amplifier is examined and tested in detail before leaving the manufacturing site to
ensure that it arrives in perfect condition at your place. Please inform the transport company immediately, if the power
amplifier shows any damage. Being the addressee, you are the only person who can claim damages in transit. Keep the
cardboard box and all packaging materials for inspection by the transport company.
Keeping the cardboard box including all packing materials is also recommended, if the power amplifier shows no external
damages. 

When shipping the power amp, make sure to always use its original box and packaging materials. Packing the power amplifier
like it was packed by the manufacturer guarantees optimum protection from transport damage.

1.3 Scope of Delivery and Warranty

1 Power Amplifier

1 Owner‘s Manual (this document)

1 Mains Cord

4 Foot Stands

1 Warranty Certificate

Keep the original invoice that states the purchase/delivery date together with the warranty certificate at a safe place.

1.4 Features and Description

Electro-Voice Q series amplifiers offer a package of reliable high output power, high efficiency and legendary pro audio
performance. They are the premium choice as system drive for a variety of mobile and club sound systems like e.g. ZX, Tour-
X and Phoenix loudspeaker families. Their comprehensive protection system includes circuitry against overheating, overload,
short circuit, HF and DC as well as back-EMF and inrush current. Loudspeakers are protected by turn-on-delay relays.
The build-in patented LPN (Low-Pass-Notch) filter compensates for transient distortion in dynamic signals (such as kick-
drums) to achieve a higher acoustic output and more punch.

1.5 Responsibility of the User

Speaker System Damage

Q power amps provide extremely high power output that might be dangerous for human beings as well as for the connected
speaker systems. High output voltages can damage or even destroy the connected speaker systems, especially, when the Q
amplifier is operated in bridged mode. Prior to connecting any loudspeakers, make sure to check the speaker system’s
specifications for continuous and peak power handling capacities. Even if amplification has been reduced through lowering
the input level controls on the amplifier’s front panel, it is still possible to achieve full power output with a sufficiently high input
signal.

Danger at the Loudspeaker/Power Outputs

Q amplifiers are capable of producing dangerously high voltage output that is present at the output connectors. To protect

yourself from electric shock, do not touch any blank speaker cables during operation of the power amp.

RF-Interference (FCC Information USA)

1. IMPORTANT: Do not modify this unit! Changes or modifications not expressly approved by the manufacturer could void the
user‘s authority, granted by the FCC, to operate the equipment.

CAUTION:
Do not ship the power amp in any other but its original packaging.

WARNING:
The terminals marked with   are hazardous live and the external wiring connected to these
terminals requires installation by an instructed person or the use of ready-made leads of
cords.

Содержание Q1212

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG ...

Страница 2: ......

Страница 3: ... Output Cabeling 9 Audio Input Cabeling 10 Operation 12 Volume Control 12 Indications 12 FAN Cooling 12 INHALT Beschreibung 16 Willkommen 16 Auspacken und Inspektion 16 Lieferumfang und Garantie 16 Eigenschaften Beschreibung 16 Verantwortung des Betreibers 16 Installation 17 Bedienelemente Anzeigen und Anschlüsse 17 Betriebsspannung 18 Netzschalter 18 Einbau 18 Kühlung 18 Groundlift 19 LPN Filter ...

Страница 4: ...60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be operated and is connected to the mains 3 Switch off the power before retrofitting any extensions changing the mains voltage or the output voltage 4 The minimum distance between parts carrying mains v...

Страница 5: ...ve for a variety of mobile and club sound systems like e g ZX Tour X and Phoenix loudspeaker families Their comprehensive protection system includes circuitry against overheating overload short circuit HF and DC as well as back EMF and inrush current Loudspeakers are protected by turn on delay relays The build in patented LPN Low Pass Notch filter compensates for transient distortion in dynamic si...

Страница 6: ...t does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to...

Страница 7: ...s A and B 2 Level Indicators for channels A and B 3 Protections Indicator PROTECT 4 Power On Off Indicator POWER 5 Mains Switch 1 Mains Input 2 Ground Lift Switch CIRCUIT TO CHASSIS SWITCH 3 Type Plate 4 Audio Inputs INPUT A INPUT B 5 Audio Outputs OUTPUT A OUTPUT B 6 Power Amp Mode Switch MODE 7 LPN Filter Switch LPN 8 Power Amp Outputs Speakon CHANNEL A CHANNEL B ...

Страница 8: ...nd screws Brackets for securing the power amplifier are available as accessories 2 5 Ventilation As with all Electro Voice power amps with fan cooling the airflow direction is front to rear obviously because there is more cold air outside of the rack case than inside The power amplifier remains cooler and dissipating the developing waste heat in a specific direction gets easier In general setting ...

Страница 9: ... like stereo operation Using the input level controls on the power amp s front panel allows independently adjusting the channels amplification PARALLEL In PARALLEL mode the inputs of channel A and channel B are directly electrically linked The audio signal has to be applied to the input connectors of channel A Using the input level controls to independently control the amplification of the two cha...

Страница 10: ...d no interfering signals are to be expected in the vicinity of the power amplifier In this case bridging the screen shielding and the pin of the inverting input inside of the connector is Speakon CHANNEL B Speakon CHANNEL A 1 1 Connector 1 1 2 2 B B Signal A A B B Table 2 1 Speaker connection using Speakon A and B connectors CAUTION In BRIDGED mode the input signal has to be fed to input channel A...

Страница 11: ...anced cabling and connections is always preferable Next to its input connector each channel provides an individual XLR type connector OUTPUT A or OUTPUT B which is connected in parallel to allow for comfortably daisy chaining the audio signal for the connection of additional audio equipment Illustration 2 2 Unbalanced connection of input Illustration 2 3 Balanced connection of output Daisy Chain 3...

Страница 12: ...l levels of each channel at 40dB 30dB 20dB and 10dB below full modulation and 0dB as soon as full modulation is reached 0dB indication results from comparing the power amp s internal ratio of input to output voltage which ensured precise indication of the full modulation limit even before limiting becomes audible The LIMIT LED lights as soon as the integrated dynamic audio limiter is activated and...

Страница 13: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual 13 ...

Страница 14: ... 16 Verantwortung des Betreibers 16 Installation 17 Bedienelemente Anzeigen und Anschlüsse 17 Betriebsspannung 18 Netzschalter 18 Einbau 18 Kühlung 18 Groundlift 19 LPN Filter Low Pass Notch 19 Betriebsart MODE und Verkabelung des Audio Ausgangs 19 Verkabelung des Audio Eingangs 21 Betrieb 22 Eingangspegel Regler 22 Anzeigen 22 Lüfter 22 Specifications Technische Daten 23 ...

Страница 15: ...erwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden führen Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind außer Sie sind hierfür qualifiziert Überlassen Sie sämtliche Servicearbeiten und Reparaturen einem ausgebildeten Kundendiensttechniker 1 Bei Reparaturarbeiten im Gerät sind die Sicherheitsbestimmungen nac...

Страница 16: ...ce bieten eine hohe stabile Ausgangsleistung bei hohem Wirkungsgrad auf hohem Performance Niveau Sie eignen sich somit ideal als Antrieb für eine Vielzahl von Mobil und Clubsystemen wie z B für Lautsprecher der ZX Tour X und Phoenix Familien Die Endstufen der Q Serie sind gegen Überhitzung Überlast Kurzschluss sowie Hochfrequenz und Gleichspannung am Ausgang geschützt Eine Beschädigung der Endtran...

Страница 17: ... bzw B 2 Pegelanzeige für Kanal A bzw B 3 Anzeige Schutzschaltung PROTECT 4 Anzeige Betrieb POWER 5 Netzschalter 1 Netzeingang 2 Schalter Groundlift CIRCUIT TO CHASSIS SWITCH 3 Typenschild 4 Audioeingangsbuchsen INPUT A INPUT B 5 Audioausgangsbuchsen OUTPUT A OUTPUT B 6 Schalter Betriebsart MODE 7 Schalter LPN Filter LPN 8 Endstufenausgangsbuchsen Speakon CHANNEL A CHANNEL B ...

Страница 18: ...entwickelt Befestigen Sie die Endstufe an der Vorderseite mit 4 Schrauben und Unterlegscheiben wie in folgender Abbildung dargestellt Wird das Rack in dem die Endstufe eingebaut ist transportiert muss die Rückseite der Endstufe im Rack befestigt werden Bei fehlender Befestigung kann sowohl die Endstufe als auch das Rack beschädigt werden Befestigen Sie die Endstufe wie in nebenstehender Abbildung ...

Страница 19: ...ückseite bestimmt die Betriebsart der Endstufe Mögliche Schalterstellungen sind DUAL PARALLEL und BRIDGED DUAL In der Betriebsart DUAL arbeiten beide Kanäle der Endstufe unabhängig voneinander Diese Betriebsart wird bei allen 2 kanaligen Anwendungen wie Stereobetrieb verwendet Über die Eingangspegel Regler an der Frontseite der Endstufe lässt sich die Verstärkung der Kanäle getrennt justieren PARA...

Страница 20: ...autsprechern die im aktiv 2 Weg Betrieb verwendet werden Bi Amp Die korrekte Anschlussweise für diese Betriebsart ist zusätzlich auf der Endstufe selbst abgebildet BRIDGED In der Betriebsart BRIDGED werden die beiden Endstufenkanäle im Gegentakt betrieben um eine Verdoppelung der Ausgangsspannung mit einer bis zu vierfach höheren Ausgangsleistung zu erreichen Das Eingangssignal ist über den Eingan...

Страница 21: ...mer Netzzuführungen HF Steuerleitungen usw ist jedoch eine symmetrische Verkabelung immer zu bevorzugen Zusätzlich zu den Eingängen steht für jeden Kanal jeweils eine parallel geschaltete XLR Buchse OUTPUT A bzw OUTPUT B zur Verfügung Über diese kann das Audiosignal komfortabel zu anderen Geräten weitergeführt werden Daisy Chain ACHTUNG Im Brückenbetrieb darf die angeschlossene Last 4 Ω nicht unte...

Страница 22: ...sgrenze erreicht ist Die 0 dB Anzeige wird endstufenintern aus einem Vergleich von Ausgangsspannung zu Eingangsspannung gewonnen und zeigt somit präzise die Aussteuerungsgrenze an noch bevor eine hörbare Begrenzung auftritt Die LIMIT LED leuchtet auf sobald einer der eingebauten dynamischen Audio Limiter anspricht und die Endstufe über der Aussteuerungsgrenze oder generell im Grenzbereich betriebe...

Страница 23: ...kHz Voltage Gain ref 1 kHz 32 0 dB Input Sensitivity rated power 8 Ω 1 kHz 2 2 dBu 1 0 Vrms 3 1 dBu 1 11 Vrms 5 1 dBu 1 39 Vrms 6 6 dBu 1 66 Vrms THD at rated output power MBW 80 kHz 1 kHz 0 03 IMD SMPTE 60 Hz 7 kHz 0 1 DIM30 3 15 kHz 15 kHz 0 05 Maximum Input Level 21 dBu 8 69 Vrms Crosstalk ref 1 kHz at rated output power 80 dB Frequency Response ref 1 kHz 10 Hz 40 kHz 1 dB Input Impedance activ...

Страница 24: ...PROFESSIONAL POWER AMPLIFIER 24 Owner s Manual Bedienungsanleitung Block Diagram Blockschaltbild ...

Страница 25: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual Bedienungsanleitung 25 Dimensions Abmessungen ...

Страница 26: ...PROFESSIONAL POWER AMPLIFIER 26 Owner s Manual Bedienungsanleitung ...

Страница 27: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual Bedienungsanleitung 27 ...

Страница 28: ...stems Telex EVI Audio Shanghai Ltd Room 3105 3109 No 1 Building No 218 Tian Mu West Road Shanghai China PC 200070 Phone 86 21 6317 2155 Fax 86 21 6317 3023 Europe Africa Middle East Germany Bosch Communications Systems EVI Audio GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 Fax 49 9421 706 265 Hong Kong Telex EVI Audio HK Ltd Unit 5 1 F Topsail Plaza 11 On Shum Street She...

Отзывы: