MAINS OPERATION & RESULTING TEMPERATURE
MAINS OPERATION
The following tables allow determining power supply and cabling requirements. The values of the
column „1/8 max. Output“ are relevant for „normal“ operation. These values are based on operating the
power amplifi er with VDE-noise at 1/8 of the maximum output power, which approximately equates the
load of the power amplifi er being operated with a music signal at maximum volume possible, without
noticeable clipping
.
RESULTING TEMPERATURE INSIDE THE POWER AMPLIFIER
The power drawn from the mains network is converted into acoustic output power to feed the connected
loudspeaker systems & heat. The difference between drawn power and dispensed power is called
leakage power or dissipation (Pd). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table provides
auxiliary means for calculating the temperatures inside of a rack-shelf system/cabinet and the ventilation
efforts necessary. The column “Pd” lists the leakage power in relation to different operational states. The
column “BTU/hr” lists the dispensed heat amount per hour
.
P1200RT
U
Mains
[V]
I
Mains
[A]
P
Mains
[W]
P
out
[W]
P
d
[W]
BTU/hr
(3)
Idling
230V
0.55
85
-
85
290
Max. Output
(1)
100V @ 40
Ω
, 70V @ 19.6
Ω
230V
6.40
1185
2 x 380
425
1450
Max. Output
(1)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
10.5
2030
2 x 600
830
2832
1⁄3
max. Output
(1)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
6.60
1230
2 x 200
830
2832
1⁄8
max. Output
(2)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
3.80
675
2 x 75
525
1791
Normal Operation (-10dB)
(1)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
3.78
670
2 x 50
570
1945
Nominal Operation (0dB)
(1)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
9.69
1870
2 x 500
870
2969
Alarm Operation (-3dB)
(1)
100V @ 20
Ω
, 70V @ 9.8
Ω
230V
7.27
1370
2 x 250
870
2969
P900RT
U
Mains
[V]
I
Mains
[A]
P
Mains
[W]
P
out
[W]
P
d
[W]
BTU/hr
(3)
Idling
230V
0.45
70
-
70
239
Max. Output
(1)
100V @ 57
Ω
, 70V @ 28
Ω
230V
4.97
920
2 x 280
360
1228
Max. Output
(1)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
8.16
1580
2 x 450
680
2320
1⁄3
max. Output
(1)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
5.13
960
2 x 150
660
2252
1⁄8
max. Output
(2)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
2.90
520
2 x 56.3
407.5
1390
Normal Operation (-10dB)
(1)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
2.84
505
2 x 35
435
1484
Nomonal Operation (0dB)
(1)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
7.32
1410
2 x 350
710
2423
Alarm Operation (-3dB)
(1)
100V @ 28.5
Ω
, 70V @ 14
Ω
230V
5.48
1030
2 x 175
680
2320
For approximation; when operating the appliance at 120V mains the stated current values need to be doubled.
(1) modulated with sine signal
(2) modulated with VDE-noise
(3) 1BTU = 1055.06J = 1055.06Ws
Содержание Precision P1200 RT
Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG ...
Страница 16: ...16 ...
Страница 17: ...BEDIENUNGSANLEITUNG ...
Страница 34: ...34 BLOCK DIAGRAM AMPLIFIER ...
Страница 36: ...36 5 5 440 5 131 483 132 5 389 5 440 DIMENSIONS ABMESSUNGEN ...
Страница 37: ...37 NOTES ...
Страница 38: ...38 NOTES ...
Страница 39: ...39 NOTES ...