background image

© Telex Communications, Inc. 02/2001

Part Number 38109-856  Rev A

U.S.A. and Canada only.

For customer orders, contact the Customer Service department at

800/392-3497  Fax: 800/955-6831

For warranty repair or service information, contact the Service

Repair department at 800/685-2606

For technical assistance, contact Technical Support at 866/78 AUDIO

Please refer to the Engineering Data Sheet for warranty information.

Specifications subject to change without notice.

Polar Response

The directional characteristics of the FC100, with driver attached,
were measured by running a set of horizontal/vertical polar
responses, in a large anechoic chamber, at each one-third-octave
center frequency. The test signal was one-third-octave,
pseudo-random pink noise centered at the indicated frequencies.
The measurement microphone was placed 6.1 m (20 ft.) from the
horn mouth, while rotation was about the waveguide geometric
apexes. These axes of rotation are quite close to the apparent
(acoustic) apexes across the frequency range of measurement.
Errors attributable to the slight differences between the geometric
and acoustic apexes are reduced to an inconsequential level by
the relatively long, 20-foot measuring distance. The horn was
suspended freely with no baffle. The polar plots shown in Figure 1
display the results of these tests. The center frequency is noted on
each plot. The wider plot on each chart is the horizontal polar (–)
and the narrower plot is the vertical polar (– – –).

Figure 1.

FC100 Polar Response

Figure 2.

FC100 Beamwidth vs. Frequency

Figure 3.

FC100 Directivity Factor and Directivity Index vs.Frequency

Beamwidth

A plot of the FC100’s 6-dB-down total included beamwidth angle is
shown in Figure 2 for each one-third-octave center frequency.

Directivity

The axial directivity factor R

θ

 

(formerly Q) of the FC100 horn was

computed at each one-third-octave center frequency from the
horizontal/vertical polars and is displayed in Figure 3.

Installation

As shipped, the “U” bracket is in position for vertical mounting. For
horizontal dispersion, or for mounts where bracket mounting holes
must be vertical, move bracket to the rear mounting position. The
horn can be mounted in a variety of horizontal and vertical
configurations by using adjustments of the swivel connections
(bracket to horn).

USA

12000 Portland Ave South, Burnsville, MN 55337, Phone: 952-884-4051, FAX: 952-884-0043

Canada

705 Progress Avenue, Unit 46,Scarborough, Ontario, Canada, M1H2X1,Phone: 416-431-4975, 800-881-1685, FAX: 416-431-4588

Switzerland

Keltenstrasse 11, CH-2563 IPSACH, Switzerland, Phone: 41/32-331-6833.  FAX: 41/32-331-1221

Germany

Hirschberger Ring 45, D94315, Straubing, Germany, Phone: 49 9421-706 392, FAX: 49 9421-706 287

France

Parc de Courcerin, Alle Lech Walesa, Lognes, 77185 Marne La Vallee, France, Phone: 33/1-6480-0090, FAX: 33/1-6480-4538

Australia

Unit 23, Block C, Slough Business Park, Slough Avenue, Silverwater, N.S.W. 2128, Australia, Phone: 61/2-9648-3455, FAX: 61/2-9648-5585

Hong Kong

Unit E & F, 21/F, Luk Hop Industrial Bldg., 8 Luk Hop St., San PO Kong, Kowloon, Hong Kong, Phone: 852-2351-3628, FAX: 852-2351-3329

Japan

2-5-60 Izumi, Suginami-ku,Tokyo, Japan 168, Phone: 81-3-3325-7900, FAX:81-3-3325-7789

Singapore

3015A Ubi Rd 1, 05-10, Kampong Ubi Industrial Estate, Singapore 408705, Phone: 65-746-8760, FAX: 65-746-1206

Mexico

Av. Parque Chapultepec #66-201, Col. EI. Parque Edo. Mex. 53390, Phone: (52) 5358-5434, FAX: (52) 5358-5588

UK

4, The Willows Centre, Willow Lane, Mitcham, Surrey CR4 4NX, UK, Phone: 44 181 640 9600, FAX: 44 181 646 7084

Africa, Mid-East

12000 Portland Ave South, Burnsville, MN 55337, Phone: 952-887-7424, FAX: 952-887-9212

Latin America

12000 Portland Ave South, Burnsville, MN 55337, Phone: 952-887-7491, FAX: 952-887-9212

www.electrovoice.com • Telex Communications, Inc. • www.telex.com

Отзывы: