18
en | Technical data for UL1480 / ULC-S541, UL1480A / CSA C22.2 NO.205
installations
EVID Surface Mount S Series - X Models
2022-03 | 07 | F.01U.345.358
Installation Manual
Electro-Voice
6
Technical data for UL1480 / ULC-S541, UL1480A / CSA
C22.2 NO.205 installations
UL1480/ULC-S541 rated frequency range: 400 Hz - 4 kHz
UL1480A/CSA C22.2 NO. 205 rated frequency
range:
55 Hz - 20 kHz
Sensitivity (SPL 1 W / 1 m)
1
: 87 dB
Power handling (@ 8 Ω): 30 W
Rated impedance: 8 Ω
Input configuration: 8 Ω; 70 V / 100 V
70 V / 100 V power taps: 8 / 15 / 30 W (70 V) 16 / 30 W (100 V)
60 W transformer tap not to be used in
UL1480 / ULC-S541, UL1480A / CSA C22.2
NO. 205 installations
Mounting system: U-Bracket
Acoustic design: Two-way design, internally damped, with
passive crossover
Approvals: UL1480 / ULC-S541, UL1480A / CSA C22.2
NO. 205; CE
Cabinet construction: UL94-5VB rated enclosure and baffle
Grille construction: Power-coated Aluminum
Included accessories: Terminal weather cover
1
Average 400 Hz to 4 kHz
UL1480 and ULC-S541 Sound level data
Voltage (Vrms)
Power Tap (W)
OSPL (dBA)
UL Reverberant
ULC Anechoic
70
8
87,8
88,9
15
90,2
91,3
30
92,5
93,9
100
16
90,5
91,8
30
92,8
94,1
15,5
8Ω (30W)
91
93,1
Содержание EVID S Series
Страница 1: ...EVID Surface Mount S Series X Models EVID S5 2XB EVID S5 2XW Installation Manual english fran ais...
Страница 2: ......
Страница 47: ......