B: Recommended installation torque is 10–14 in/lb (1.13–1.58 Newton Meters)a
B
Figure 4.13: Tighten four (4) screws to attach
the cover and tighten the gland nut
Figure 4.14: Weatherized terminal cover is attached
!
Caution!
When using the weatherized terminal cover, the original auxiliary support ring is no longer
used. Attach the safety cable to the auxiliary support ring on the weatherized terminal cover.
!
Caution!
Ceiling mount speaker’s safety cable
The safety cable should be installed with a minimum of 3-inches (76.2 mm) of slack.
C: Recommended auxiliary support line slack is 76.2 mm–305 mm (3 in–12 in).
C
Figure 4.15: Attach auxiliary support line
Figure 4.16: Install the speaker into the ceiling
EVID High Performance Ceiling Speakers
2017.01 | 02 | F.01U.321.491