![Electro-Voice EVA-1151D Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/electro-voice/eva-1151d/eva-1151d_user-manual_2380826033.webp)
Electro-Voice EVA Series User Manual
33
6.4 Special rules when flying EVA-2151D Subwoofer Modules
EVA-2151D subwoofers may ONLy be flown from an EVA-EG2 grid. Because the EVA-2151D modules
have six rigging points instead of four, the maximum load ratings are higher, but also require special condi-
tions to achieve. Please read, understand and observe the following:
1.
When flying EVA-2082S full-range modules below EVA-2151D subwoofer modules, the
maximum number of EVA-2151D modules is TWO and the maximum number of EVA-
2082S modules is FIVE. A bottom pull-up point may be used as long as the maximum
angle on the grid does not exceed 45° and the maximum pull angle between suspension
lines does not exceed 60°. Maximum single-point column weight when using EVA-2151D
subwoofers is
840 lb (381 kg)
.
2.
When flying EVA-2151D subwoofer modules as a stand-alone subwoofer array using the
center attachment point on the spreader bar(s), the maximum number of EVA-2151D mod-
ules is FOUR, even if two spreader bars are used. For extreme down angles, a second
EVA-EG2 grid may be attached at the bottom of the array for use as a pull-up point as long
as the maximum pull angle between suspension lines does not exceed 60°.
3.
When flying FIVE or more EVA-2151D modules, use only the two outermost attachment
holes on the spreader bar. If two spreader bars are used, the two outermost attachment
holes must be used ON EACH BAR. A maximum vertical column of EIGHT EVA-2151D
modules is permissible under these conditions if the column is kept perpendicular to the
ground. The maximum suspended column weight of EVA-2151D subwoofers in a stand-
alone subwoofer array with 0° of inclination (tilt) angle using both outer attachment points
on the spreader bar is
1,470 lb (667 kg)
. See Figure 24.
6.0 Rigging-Strength Ratings and Safety Factors (cont’)
Figure 24:
EVA-EG2 grid with more than (4) EVA-2151D’s in a straight (vertical)
array must use outer holes of spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
Any Array with more
than (4) EVA-2151D’s
must use the two
outermost attach-
ment holes on the
spreader bar
NEVEr ATTEMPT TO SuSPEND EVA SySTEMS OVErHEAD By ANy OTHEr METH-
OD THAN THE uSE Of EVA-SG2, EVA-EG2 Or EVA-CG GriDS AND SPrEADEr
BArS AS OuTLiNED iN THiS MANuAL! EVA-1151D MODuLES MAy BE SuSPEND-
ED frOM iNVErTED EVA-1151D TiE PLATES ONLy iN CONjuNCTiON WiTH AN EVA-GXB
SPrEADEr BAr (SOLD SEPArATELy).