3
MEASURED SPECIFICATIONS: CPS4 entire unit
Measurement conditions, unless differently specified:
•
tolerance of measured values:
∆
X = ±1.5 dB
•
measuring frequency:
f = 1 kHz
•
stated levels refer to:
U = 775 mV (0 dBu)
•
level controls set to their clockwise limits
•
pin assignment of the XLR-type connectors:
PIN 1: GROUND
PIN 2: + INPUT
PIN 3: - INPUT
•
source resistance for the induction via the XLR-type connector:
R(Q) = 50
Ω
•
MAIN-PCB numbers relate to the models as follows:
MAIN - PCB
CPS4 / 120 V
86211
CPS4 / 230V
86207
•
MAIN-PCB and POWER-AMP-PCB are provided with service connectors.
The Pin-assignment of these service connectors is as follows:
84157
86207
86211
86207
86211
CNSERV
Assignment
CNASERV
Assignment
CNBSERV
Assignment
1
Kodierung
1
Limiter A
&
B OFF
1
n.c.
2
BIAS Hot - Side +
2
Service Limiter A
2
Service Limiter B
3
BIAS Hot - Side -
3
-15V
3
- 15 V
4
Hot - Out
4
GND
4
Fan voltage
5
BIAS Cold - Side +
5
+ 15 V
5
Service Fan
Switch
6
BIAS Cold - Side -
6
heat sink temperature
A
&
B
6
Service Fan
Switch
7
GND
7
+ U1 front-end A
7
+ U1
front-end B
8
floating v
8
- U1 front-end A
8
- U1
front-end B
9
floating voltage -
9
coding
9
coding
1.
Operating voltage:
U(B) = 120V/ 230V/ 240V
depending on the model:
50Hz ... 60Hz
2.
Deviation limit of the operation voltage:
±10%
3.
Power consumption (both channels driven):
3.1.
at idling condition
P(B) = 180 - 260 W
3.2.
at standard operation (120W/4
Ω
)
P(B) = 1500 W
3.3.
at nominal condition (1200W/4
Ω
)
P(B) = 4100 W
3.4.
at 1/8 of the nominal power (150W/4
Ω
)
P(B) = 1650 W
4.
Settings / Adjustments
4.1. IDLING CURRENT ADJUSTMENT
Connect the DC-volt meter at the BIAS measuring points (refer to table) and adjust the idling current via the trim
potentiometer (on the printed board assembly 84157). Adjust both channels of the power amplifier A&B.
Setting
Measuring point 1
Measuring point 2
U (DC)
BIAS trimmer
BIAS HOT A
CNSERV 2
CNSERV 3
15 mV
VR1
BIAS COLD A
CNSERV 5
CNSERV 6
15 mV
VR2
BIAS HOT B
CNSERV 2
CNSERV 3
15 mV
VR1
BIAS COLD B
CNSERV 5
CNSERV 6
15 mV
VR2
Adjusting the idling current has to be performed at normal room temperature. In case the power amplifier had
previously been operated, it has to be given several hours to cool off.
All manuals and user guides at all-guides.com
Содержание CONTRACTOR PRECISION SERIES
Страница 18: ...All manuals and user guides at all guides com ...
Страница 19: ...All manuals and user guides at all guides com ...
Страница 20: ...All manuals and user guides at all guides com ...
Страница 21: ...All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 22: ...All manuals and user guides at all guides com ...
Страница 23: ...All manuals and user guides at all guides com ...
Страница 24: ...All manuals and user guides at all guides com ...
Страница 25: ...All manuals and user guides at all guides com ...
Страница 26: ...All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 27: ...All manuals and user guides at all guides com ...
Страница 28: ...All manuals and user guides at all guides com ...
Страница 29: ...All manuals and user guides at all guides com ...
Страница 54: ...All manuals and user guides at all guides com ...