1. Level Control

To prevent unauthorized operation of the level controls on the CPS3 and CPS4, they are provided with
screwed-on protective cover lids. When shipped from the factory, the detented potentiometers are set to
their clockwise limits. Thus, the input signal is not attenuated. In case matching the input levels is required,
you first have to detach (unscrew) the cover lids to gain access to the potentiometers.

2. POWER ON INDICATION

This LED lights up when the mains switch is pressed. If it does not light up, the unit is not connected to
the mains or the mains fuse has blown.

3. INPUT INDICATION

This LED lights up if a signal is present at the power amplifier input. The indicator does not light up when
the input controls are turned down completely.

4. OUTPUT INDICATION

This LED lights up if a signal is present at the power amplifier output. The indicator goes off when the
speaker line has shorted or a protective circuit has been activated thus indicating that there is no signal
at the speaker output terminals.

5. LIMIT

This LED lights up if the limiter has been activated and the power amplifier is being operated at the clip
level. If the LED flashes briefly, this is not a cause for concern. If this LED is lit permanently, the volume
should be reduced to avoid overload damages to the connected loudspeaker systems.

6. PROTECT

When this LED lights up during operation, one of the protection circuits against over-temperature,
overload, shorted outputs, radio frequency interference or DC faults has been triggered. The cause of the
error e.g. a shorted loudspeaker line must be remedied. In case of overheating, wait a little until the
amplifier switches back to operating mode itself.

7. POWER Switch     

The unit is switched on via the power switch. The loudspeaker outputs are switched on via delayed relays
so that no startup transients are audible. A current limiter prevents startup peaks on the mains line and
prevents the mains fuse from blowing.

FRONT PANEL

10

Содержание Contractor Precision CPS3

Страница 1: ...OWNER S MANUAL CPS 3 CPS 4 CONTRACTOR PRECISION SERIES...

Страница 2: ...into your outlet consult an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the a...

Страница 3: ...by far No V I Foldback Limiter circuits are employed within the power amplifiers making it possible to operate the amps on complex loads up to 90 phase angles without a problem The input facilities a...

Страница 4: ...eaker line has shorted or a protective circuit has been activated thus indicating that there is no signal at the speaker output terminals 5 LIMIT This LED lights up if the limiter has been activated a...

Страница 5: ...0 dBu The power amplifier can be set internally to 6dBu input sensitivity or to 26dBu gain INPUT ROUTING PARALLEL MONAURAL Setting the selector switch to the PARALLEL MONO position puts the channel A...

Страница 6: ...ode the built in power ampli fiers operate in push pull and the double output voltage from channel A and B appears at the Bridged output connector The phases of Channel A and B are in oppo site and th...

Страница 7: ...Sensitivity 0dBu 775mV at rated output power 4 1 kHz THD at rated output power 0 05 MBW 80kHz 1 kHz IMD SMPTE 0 01 60 Hz 7 kHz DIM30 0 01 3 15kHz 15 kHz Crosstalk 70 dB ref 1kHz at rated output power...

Страница 8: ...BLOCK DIAGRAM 20...

Страница 9: ...Abmessungen Dimensions in mm ABMESSUNGEN DIMENSIONS 21...

Отзывы: