                                                     CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

1. Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when 

servicing the appliance.

2. Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs  to be 

operated and is connected to the mains

3. Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.
4. The  minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure),

respectively between the mains poles has to be 

3 mm

 and needs to be minded at all times.

The  minimum distance between parts carrying mains voltage and any switches or breakers that are not connected 
to the mains (secondary parts) has to be 

6 mm

 and needs to be minded at all times.

5. Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible

when using original parts.

6. Altering the circuitry without prior consent or advice is not legitimate.
7. Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly

obeyed. This applies also to any regulations about the work place itself.

8. All instructions concerning the handling of 

MOS

 - circuits have to be observed.

Note:

  

  

SAFETY COMPONENT  (HAS TO BE REPLACED WITH ORIGINAL PART ONLY)

IMPORTANT SERVICE INSTRUCTIONS

CAUTION:  These servicing instructions are for use by qualified personnel only. To reduce the

risk of electric shock, do not perform any servicing other than that contained in the 
Operating Instructions unless you are qualified to do so. Refer all servicing to 
qualified service personnel.

1. 

Read these instructions.

2. 

Keep these instructions. 

3. 

Heed all warnings.

4.

Follow all instructions.

5. 

Do not use this apparatus near water.

6.

Clean only with a damp cloth.

7. 

Do not block any of the ventilation openings. 
Install in accordance with the manufactures instructions.

8.

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.

9.

Only use attachments/accessories specified by the manufacturer.

10.  

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any
way, 

such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,

the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

For US and CANADA only:

Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an
electrican for replacement of the absolete outlet.

The lightning flash with arrowhead symbol, within an equilateral

triangle is intended to alert the user to the presence of uninsulated

“dangerous voltage” within the product’s enclosure that may be of

sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to

alert the user to the presence of important operating and maintan-

ce (servicing) instructions in the literature accompanying the

appliance.

IMPORTANT SAFETY INSTRUCTIONS

8

Содержание Contractor Precision CPS2

Страница 1: ...OWNER S MANUAL CPS 1 CPS 2 CONTRACTOR PRECISION SERIES ...

Страница 2: ...c shock do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with a damp cloth 7 Do not block any of the ventilation openings Install...

Страница 3: ...90 phase angles without a problem The electronically balanced inputs are provided via XLR type and PHOENIX connectors which are also used to loop the signal through Using the Input Routing switches lets you determine if the CONTRACTOR PRECISION SERIES amplifiers are operated in DUAL stereo or PARALLEL monaural mode mono bridged operation is also possible The dB scaled level controls are to be foun...

Страница 4: ...r engaging the power switch either the amplifier is not connected to the mains or the internal mains fuse has been blown and it needs to be replaced 4 PROTECT If this indicator lights during operation one of the amp s internal protection functions against thermal overload short circuit or the occurrence of HF at the output has been engaged The cause that let the amplifier enter the protection mode...

Страница 5: ...mplification These controls should be set between 0 dB and 6 dB depending on the output of the connected signal source device e g a mixing console The printed scale shows the actual amount of damping in the amplification of the power amplifier INPUT ROUTING PARALLEL MONAURAL Setting the selector switch to the PARALLEL MONO position puts the channel A and channel B inputs in electrically direct par...

Страница 6: ...power amp The two amplifiers A B are now used in push pull operation providing the double output voltage at the BRIDGED OUT connector The regular output voltages of the power amplifiers A and B are still present at the individual output connectors CHAN NEL A and CHANNEL B but in respect to the inverted phase using these signals is not recommendable Bridged mode operation with loads of 2 ohms is no...

Страница 7: ...ximum output power 4 Ω Input Sensitivity 1Vrms at rated output power 8 Ω 1 kHz THD at rated output power 0 05 MBW 80kHz 1 kHz IMD SMPTE 0 08 60 Hz 7 kHz DIM30 0 03 3 15kHz 15 kHz Crosstalk 80 dB ref 1kHz at rated output power Frequency Response 1dB ref 1 kHz 10Hz 45kHz Power Bandwith THD 1 ref 1kHz half power 4 Ω 10Hz 50kHz Input Impedance 20Hz 20 kHz balanced 20kΩ Damping Factor at 100Hz 1kHz 300...

Страница 8: ...BLOCK DIAGRAM 20 ...

Страница 9: ...Abmessungen Dimensions in mm ABMESSUNGEN DIMENSIONS 21 ...

Отзывы: