SA420 Signal conditioner

 

For version 3 hardware with version 5.xx or later firmware

The SA420 now includes the following features:

• 

Quadrature (directional decoding)

• 

Bipolar voltage output (units now i/- 5 VDC and +/- 10 VDC)

• 

Optional higher NPN input signal trip point (improves operation through IS barrier)

• 

Programmable lower analog output setpoint (Previously fixed at 0 Hz, now includes forward and reverse offsets) PR (00)

• 

Programmed to power up and display in the following units PR (04):

 

• Hz (default)

 

• Percent of maximum output

 

• User defined units

• 

Programmable minimum frequency cutoff. PR  (05) (This allows you to decide where the unit zeroes out for faster zeroing)

• 

More modes of operation:

 

• Single channel

 

• Quadrature 1X

 

• Single channel 2X (new)

 

• Quadrature 2X (new)

 

• Quadrature 4X (new)

• 

Security lock variables (viewable but not changeable while locked)

• 

Ability to improve calibration with user variables which alter the upper and lower calibration point of the analog

• 

Choice of new menu or revert to basic 3 variable menu for compatibility

Free Catalog and Application Assistance

1.800.328.6170

Website: www.electro-sensors.com

990-001700 Revision I

2-8

Содержание SA420

Страница 1: ...o achieve the proper gap distance adjust the jam nuts holding the standard sensor in the mounting bracket or adjust the position of the explosion proof sensor using the slots on its mounting bracket P...

Страница 2: ...wing units PR 04 Hz default Percent of maximum output User defined units Programmable minimum frequency cutoff PR 05 This allows you to decide where the unit zeroes out for faster zeroing More modes o...

Страница 3: ...the calibration mode Programming The Unit Standard menu To enter the calibration mode push the ENT button once PR0 will be displayed Press the up button to increment to the desired variable Press the...

Страница 4: ...o slew from 10 90 analog output PR 07 Signal Type Programming of PR 07 determines the way the signals are handled There are multiple choices for both single and quadrature operation 1X uses the rising...

Страница 5: ...is approximately 366nA 0 000366uA of deviation up or down per single count of change Example of changing this from 1000 to 980 results in the analog decreasing It will decrease 20 0 000366uA or 0 007...

Страница 6: ...0 0 5 VDC 1 0 10 VDC 2 5 VDC 3 10 VDC No 09 MENU_OPTION_VAR 1 0 1 0 Basic menu 1 Advanced menu Standard No 10 DISPLAY_OPTION_VAR 0 0 2 0 Hz 1 Percent output 2 User units No 11 reserved for future use...

Страница 7: ...Disc 2 00 2 51 2 00 2 00 1 25 1 00 1 00 1 120 Figure 9 Standard Sensor 2 38 5 53 1 16 3 38 1 00 1 NPT 1 63 3 75 1 88 Nut Lockwasher 0 56 1 25 4 63 Figure 10 Explosionproof Sensor 1 00 43 0 13 2 75 1...

Страница 8: ...hysical Envlronment Parameters Mounting DIN rail mount or Stand alone Operating temperature 0 C to 60 Cz Storage temperature 65 C to 125 C Electrical Connections 11 Position DIN rail terminal block DI...

Отзывы: