background image

INTRODUCTION 

 

DESCRIPTION

 

 
The MPRS1000 Sourcer is a self-contained 
Electronic Air Cleaner comprised of a two-part 
collecting cell, an electrical compartment, two blower 
and motor assemblies, complete cabinet housing, a 
flex arm (direct capture system), prefilter and an 
after filter or optional carbon filter. 
 
 

HOW IT WORKS

 

 
The MPRS1000 Sourcer operates on the principle of 
“Electrostatic Precipitation”. Airborne pollutants are 
drawn in though the direct capture arm and first pass 
through to the prefilter, where large particles are 
caught. Next, smaller particles move to a two-stage 
electrostatic collecting cell where they are given a 
powerful positive charge by the ionizing wires. 
Charged particles then move into the collecting area 
where they are attracted to a series of alternately 
charged and grounded plates. Pollutants are held on 
the plates like a magnet until washed away during 
cleaning. Clean air is then dispersed from the top of 
the unit.  

 

 

MAJOR COMPONENTS 

 

CABINET

 

 
The cabinet is built of heavy gauge steel finished in a 
scratch-resistant electrostatic powder coated finish. 
There is an access door (interlocked) on the unit to 
service the ionizer, cell and filters. There is a 
separate removable panel to access the motor/ 
blower section. 

 
 

PREFILTERS

 

 
The washable prefilter, measuring 16 x 20 in. (40.6 x 
50.8 cm), is constructed of multi-layers of aluminum 
mesh for maximum filtration of large particles. 
 

AFTER FILTER 

 
The after filter, measuring 16 x 20 in. (40.6 x 50.8 
cm), is constructed of multi-layers of aluminum mesh 
for filtration of agglomerated dust, and to maintain 
back pressure. 
 
 

COLLECTING CELL

 

 
The two part collecting cell includes support 
brackets, collecting plates, support tubing, insulators, 
end plates, spring contact, carrying handles, and 
separate ionizing section (ionizing wires, ionizing 
wire support). 
 

MOTOR & BLOWER 

 
Two AC motorized centrifugal impellers are utilized 
to draw air evenly across the face of the cell. The 
single inlet blower wheels are backward curved, 
measuring 9 in. diameter by 4 in. wide (22.9 x 10.2 
cm). The energy efficient, ball bearing fan motors 
draw only 185 watts each. 
 

ELECTRICAL COMPARTMENT

 

 
The removable power box contains the safety 
interlock, system and high voltage switches, high 
voltage power board and performance indicator light.   
 
The power board is an open printed circuit board 
with an adjustable output. The direct current output 
is 10,000 volts @ 3.5 mA. The board is fused at 1.5 
amps.  A large value bleed off resistor allows the 
high voltage to dissipate from the cell when the unit 
has been turned off, to prevent shock. 
 
Quick disconnects on the board allow for easy 
removal for troubleshooting or repairs. 

The 

Performance Indicator Light should be on during 
normal operation. 

The light will flicker with arcing in 

the cell or extinguish if the cell, ionizer or power 
board is shorted. 
 

Certified for shock and electrical fire hazard only. 

Electrostatic Precipitation 

 

2 Prefilter 

1 Dirty Air 

3 Ionizing Section 

4 Collecting Cell Plates 

6 Clean Air 

5 After Filter or 
Carbon Filter 
(optional) 

Содержание MPRS1000 SOURCER

Страница 1: ...OPERATION MAINTENANCE MANUAL MODEL MPRS1000 SOURCER MOBILE PARTICULATE REMOVAL SYSTEM ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT...

Страница 2: ...TER The after filter measuring 16 x 20 in 40 6 x 50 8 cm is constructed of multi layers of aluminum mesh for filtration of agglomerated dust and to maintain back pressure COLLECTING CELL The two part...

Страница 3: ...ilter it will need to be refilled depending on the environment every 3 6 months Do not wash the carbon filter as this will render it useless WASHING INSTRUCTIONS 1 Turn both the high voltage and syste...

Страница 4: ...the cell should be removed at least twice a year with a vacuum Dry compressed air can be used to remove the dust in the power box which houses the high voltage power supply Do not apply air pressure...

Страница 5: ...y service center The installing dealer should have sufficient knowledge to determine any problems Removing Power Box From Air Cleaner Before removing the power box from the air cleaner unplug the unit...

Страница 6: ...asket 17 IS 0642 Flex Arm Hose Only for 7 Ft Arm 18 IS 0644 Clamp For Flex Arm Hose 19 IS 0690 Scoop or Intake Hood 1 4 x 3 8 x 21 64 x 95 x 53 3 cm Part Description 20 IS 052D Industrial Power Board...

Страница 7: ...Gasket 1 A 3 8 16 x 1 in Bolt Split Washer 6 A Tension Springs 6 1 2 in 2 A Rod 3 8 in 1 A 1 4 20 x 1 in Bolt 2 C 1 4 20 Nut 2 C Spacer Nylon 1 4 in 2 C Spacer Steel 3 1 2 in 2 A B Bolt 3 8 16 x 5 1 2...

Страница 8: ...o voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corro...