4.  Before replacing the lamps, the reflector should be 

cleaned  with  a  soft  cloth  and  mild  non-abrasive 

soap.  

5.  Replace  the  support  clips  by  pressing  them  into 

the hole in the reflector. 

6. 

NEVER

  use  any  lamp  other  than  from  the 

original manufacturer. 

NEVER

 run the Air Cleaner 

with only one lamp. 

7.  When  replacing  the  lamp,  use  gloves  to  prevent 

oil  from  being  deposited  on  the  glass.  Hold  the 

lamp by the base and slide the glass end into the 

plastic support clip. Slide the lamp straight into the 

lamp socket until the lamp locks into place. 

8.  Remove the new PCO filter from the bag and slide 

into  the  upper  track  above  the  lamps  with  the 

fuzzy  side  down  towards  the  lamps.  During 

shipping  and  handling  a  small  amount  of  white 

dust  is  created.  This  can  be  cleaned  by 

vacuuming. 

DO NOT

 vacuum the filter. 

9.  Remove  the  final  filter  from  the  bag  and  slide  it 

into the track above the PCO filter with the arrow 

pointing up. 

Note:  The  Air  Cleaner  will  not  operate  with  this 

filter removed.

 

10. 

Replace  the  lamp  access  panel  tightening  all 

screws. Do not over tighten.

 

The  PCO  Filter  will  discolor  with  use.  This  is 

normal. 

 
 
 
 
 
 
 
 
 

 
PCO  Filter  (#DM900-0450):

 This must be replaced 

every 2-3 years.  

Final  Filter  (#DM900-0810):

 This must be replaced 

at least once a year.  

UVC  Lamp  (#DM900-0191)  (2  required):

  Replace 

every  2-3  years.  Includes  lamp  support  clip.  Lamp 

may  still  light  after  2  years  but  intensity  of  the 

germicidal wavelength will be reduced. 

UVC Lamp / PCO Maintenance Kit (#DM900-1002): 

Kit  contains  2  UVC  lamps,  2  lamp  support  clips,  1 

PCO filter and gloves. 

Complete  2-3  Year  Maintenance  Kit  (#DM900-

1003): 

Contains  1  HEPA  filter,  4  carbon  prefilters,  2 

UVC  lamps,  1  PCO  filter,  2  carbon/potassium 

permanganate final filters, gloves. 

WARNING  

Eye and skin damage may result from direct exposure to 

the  light  produced  by  the  lamps  used  in  this  product. 

Make  sure  the  Air  Cleaner  is 

OFF

  and 

UNPLUGGED

 

before the lamp access panel is open. 

CAUTION  

Do  not  touch  the  lamp  glass  with  bare  hands.  Always 

use the gloves provided when installing the lamps. The 

oil from your hands may reduce the effectiveness of the 

lamp.  The  lamp  may  be  cleaned  with  a  soft  cloth 

dampened with water to remove finger prints. 

CAUTION  

The lamps operate at a very high temperature. Allow the 

lamps to cool 10 minutes before touching. 

WARNING  

Never  use  the  Air  Cleaner  without  all  of  the  filters  in 

place and all cover panels and doors closed. Make sure 

all the screws are in place. 

CAUTION 

When  the  unit  is  new  or  after  the  lamps  have  been 

replaced  there  may  be  a  temporary  odor.  An  odor may 

also  occur  with  high  concentrations  of  chemicals  in  the 

home  such  as  paint  or  strong  cleaning  solutions.  Both 

odors are temporary and should dissipate within a short 

time.  

CAUTION  

Always  dispose  of  plastic  bags  safely.  Do  not  allow 

children or pets to play with empty plastic bags. 

CAUTION  

The  lamps  contain  a  very  small  amount  of  mercury 

(Hg).  In  case  of  accidental  breakage,  handle  with 

extreme  care.  According  to  the  EPA  website,  open 

windows in the affected area and leave the room for 15 

minutes.  Do  not  vacuum  or  use  a  broom  to  clean. 

Wear  a  dust  mask  and  use  disposable  gloves.  Scoop 

fragments  using  stiff  paper  or  cardboard.  Place 

fragments in a plastic bag. Wipe area with damp paper 

towels  and  place  towels  in  the  plastic  bag.  Seal  bag 

and dispose of waste following local guidelines. Wash 

hands  with  mild  detergent  and  water.  See  the  EPA 

website (www.epa.gov) for more information. 

CAUTION  

The lamps used in this air cleaner contain a very small 

amount  of  mercury  (Hg).  The  lamps  should  be 

disposed  of  according  to  local  ordnances  or  refer  to 

www.lamprecycle.org. 

Содержание EAP900

Страница 1: ...put Ultraviolet Germicidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases...

Страница 2: ...the unique CinQuartz Media located above the UVC lamps The CinQuartz Photo Catalytic Oxidation PCO Filter is a Quartz media coated with nanoparticles of Titanium Dioxide TiO2 The combined action of t...

Страница 3: ...ants will shorten the life expectancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UVC Lamps PCO Fi...

Страница 4: ...es 4 WARNING Eye and skin damage may result from direct exposure to the light produced by the lamps used in this product Make sure the Air Cleaner is OFF and UNPLUGGED before the lamp access panel is...

Страница 5: ...dangerous voltage or other hazards Refer all servicing to qualified personnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or...

Страница 6: ...this warranty THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS incurred for diagnosis repairing removing installing shipping servicing or handling of either defective parts...

Страница 7: ......

Страница 8: ...PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES...

Отзывы: