background image

flexible 12 inch intake duct, from the cold air return, 
to be attached. The 12 inch intake must be drawn 
from  the  cold  air  return  duct  at  a  location  that  will 
be  ahead  of  the  clean  exhaust  air,  that  will  be 
returned to the duct from the Air Cleaner. 

4.  A duct adapter and a length of 12 inch flexible hose 

or  duct  is  required  to  attach  between  the  12  inch 
intake  collar  and  the  existing  cold  air  return  duct.  
When  running  the  hose,  make  sure  that  there  are 
no  kinks  or  sharp  bends  that  will  impede  the  air 
flow  to  the  unit.    Secure  and  seal  the  hose  and 
connections to prevent air leakage. 

5.  The  8  inch  exhaust  collar  can  be  conveniently 

mounted on either side of the unit. A duct adapter 
and  a  length  of  8  inch  flexible  hose  or  duct  is 
required  to  attach  between  the  exhaust  collar  and 
the  existing  cold  air  return.  The  exhaust  hose 
should  be  attached  to  the  return  air  duct,  close  to 
the furnace. The ideal location is low on the return 
air  boot  pointing  at  the  furnace.  To  prevent  air 
shear  inside  the  duct,  it  is  recommended  that  you 
install a deflector inside the boot, so the discharged 
air  is  deflected  down  into  the  boot. When  running 
the  hose,  make  sure  that  there  are  no  kinks  or 
sharp bends that  will impede the air flow from the 
unit.  Secure and seal the hose and connections to 
prevent air leakage. 

6.  It  is  important  to  maintain  some  distance  between 

the  intake  and  the  exhaust  openings  in  the  return 
air  duct.  Failure  to  do  this  may  result  in  short 
cycling  between  the  intake  and  the  clean  air 
discharge.  It  is  recommended  you  leave  10  feet 
between  the  intake  and  the  exhaust;  however,  as 
little as 6 feet will work effectively. If the distance is 
smaller  than  6  feet,  it  is  important  that  an  air 
deflector is installed in the duct. 

7.  If  outside  air  is  introduced  into  the  return  air  duct, 

either through a HRV (Heat Recovery Ventilator) or 
direct, it should be added to the system before the 
intake inlet to the Air Cleaner.  

OPERATING INSTRUCTIONS

 

The HEPA Air Cleaner is designed to run continuously 
to provide clean, filtered air 24 hours a day. The fan on 
the  heating/cooling  system,  to  which  the  HEPA  Air 
Cleaner  is  dependent  on  for  circulated  air,  should  be 
on ‘continuous’. 

Note:   

If the system fan setting is on  ‘automatic’, it is 

recommended  the  HEPA  Air  Cleaner  be  operated 
through  an  air  switch  or  relay  to  turn  the  Air  Cleaner 
off, when there is no system fan on. 

The  unit  plugs  into  a  regular  120  volt  outlet  and  is 
controlled  by  a  switch  located  on  the  rear  panel,  near 
the cord. 

Note:

  Do not allow the cord to be placed where it may 

be walked on or allow anything to roll over it. 

The  door  must  be  secured  for  the  Air  Cleaner  to 
operate, as the door is interlocked for safety.  All filters 
must be in place for the unit to operate properly. 

MAINTENANCE

 

For efficient operation, the filters must be changed on a 
regular basis. If you notice a reduction in air flow from 
the system, check the filters.  
1.  To  access  the  filters,  turn  the  Air  Cleaner 

OFF

  at 

the switch and remove the front door. 

2.  Carefully remove filters to avoid spilling of collected 

contaminants.  Dispose  filters  in  a  plastic  bag  and 
discard with regular household trash. 

3.  Remove  plastic  from  new  filters  before  installing. 

Discard plastic safely. Take care not to damage the 
filters. 

4.  Date the replacement filters in the space provided. 
5.  Ensure that the direction arrow on filter is pointing 

toward the fan blade. 

6.  Use  genuine  replacement  filters  only.  Call  the 

original installer for parts. 

Note:

  When the filters are new, you may notice a new 

smell from the system. This is normal and will dissipate 
within a few days. 

Carbon  Prefilter  (Part  #W5-0810):

    This  must  be 

replaced  every  3  -  6  months  and  may  be  vacuumed 
between  changes.  Use  a  soft  brush  attachment  when 
cleaning. 

True  HEPA  Filter  (Part  #W5-0860-3):

  Replace every 

3-5 years. The life of this filter depends on the amount 
of  contaminants  in  the  air  and  the  frequency  in  which 
the  prefilter  has  been  changed.  Renovations  in  the 
home  that  create  wood,  drywall  dust  or  similar 
contaminants  will  shorten  the  life  expectancy  of  the 
HEPA filter. 

Note:

    Handle  the  HEPA  filter  by  the  frame  only.  The 

paper  is  fragile  and  a  puncture  or  tear  will  reduce 
efficiency. 

VOC  After  Filters:

 The 2 inch standard or heavy-duty 

optional upgrade filters must be replaced every 6  - 12 
months.  If  there  are  heavy  odors  in  the  home  from 
cooking,  smoking,  painting  or  other  sources,  the  filter 
may require changing more often. 
 

Replacement VOC After Filters (2 inch): 

Carbon Filter 

 

 

            Part #W5-0820 

 

Carbon/Potassium 
Permanganate Filter 

 

            Part #W5-0885 

WARNING  

Never use the unit without all of the filters in place.  

CAUTION  

Make sure to turn Air Cleaner 

OFF

 before performing 

any maintenance or removing any components.  

CAUTION  

The  new  HEPA  filter  may  be  tight  to  install  the  first 
time. Do not push from the center of filter. Apply even 
pressure at both corners.  

Отзывы: