AFTER INSTALLING AIR CLEANER

 

1.  Install the two UVC lamps into the lamp holders. 

Follow the instructions given in the maintenance 
instructions.  Use  the  cotton  gloves  provided 
when  handling  the  lamps.  Replace  the  four 
filters  (see  Fig.  5),  close  the  filter  access  door 
and replace the lamp access panel. 

Ensure  all 

the screws are in place and tight. 

Do not over 

tighten. 

2.  After  the  installation,  the  unit  must  be  checked 

for  sealing,  both  for  air  and  light  leakage.  Any 
leaks  to  the  Air  Cleaner  must  be  sealed  with 
aluminum tape. 

3. 

Turn  the  Air  Cleaner  ON  and  check  for  any 
leaks of light. There must be no visible blue light 
from  the  Air  Cleaner.  If  you  see  any  blue  light 
from  the  duct  connections  cover  the  holes  with 
aluminum tape.

 

OPERATING INSTRUCTIONS

 

The Air Cleaner is designed to run continuously to 
provide  clean,  filtered  air  24  hours  a  day.  The  fan 
on  the  heating/cooling  system,  to  which  the  Air 
Cleaner  is  dependent  on  for  circulated  air,  should 
be on ‘continuous’ setting. 

Running  the  Air  Cleaner  intermittently  will 
shorten the effective life of the lamps.

 

The Air Cleaner plugs into a regular 120 volt outlet 
and is controlled by a switch located on the side of 
the unit, near the cord. 

Note:

  Do  not  allow  the  cord  to  be  placed where  it 

may be walked on or allow anything to roll over it.

 

 

MAINTENANCE

 

For efficient operation, the filters must be changed 
on  a  regular  basis.  If  you  notice  a  reduction  in  air 
flow from the system, check the filters.  

 

WARNING  

Never  use  the  Air  Cleaner  without  all  of  the  filters  in 
place  and  all  cover  panels  and  doors  closed.  Make 
sure all the screws are in place. 

CAUTION  

Make  sure  to  turn  the  Air  Cleaner 

OFF

  before 

performing any maintenance or removing any filters. 

CAUTION 

When  the  unit  is  new  or  after  the  lamps  have  been 
replaced there may be a temporary odor. An odor may 
also occur with high concentrations of chemicals in the 
home such as paint or strong cleaning solutions. Both 
odors  are  temporary  and  should  dissipate  within  a 
short time.  

WARNING  

Eye and skin damage may result from direct exposure 
to the light produced by the lamps used in this product. 
Make  sure  the  Air  Cleaner  is 

OFF

  and 

UNPLUGGED

 

before the lamp access panel is open. 

CAUTION  

Do  not  touch  the  lamp  glass  with  bare  hands.  Always 
use the gloves provided when installing the lamps. The 
oil  from  your  hands  may  reduce  the  effectiveness  of 
the  lamp.  The  lamp  may  be  cleaned  with  a  soft  cloth 
dampened with water to remove finger prints. 

Fig. 4 – Self-Contained Attic Installation 

 

Prefilter 
 
HEPA Filter 
 
Filter Access 
Door 
 
 
 
UVC Lamps 
 
 
PCO Filter 
 
 
 
 
Final Filter 
 
Lamp Access 
Removable 
Panel 

Fig. 5 – Air Cleaner Layout 

Содержание DM900UV-VO-WHT-VS

Страница 1: ...icidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits b...

Страница 2: ...ime and redecorating costs Provides a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling sys...

Страница 3: ...the holes on the top or bottom of the unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 d...

Страница 4: ...direct it should be added to the system before the intake inlet to the Air Cleaner 5 The 8 inch intake collar top must draw air from the return duct at a location that will be ahead of the clean exha...

Страница 5: ...cord to be placed where it may be walked on or allow anything to roll over it MAINTENANCE For efficient operation the filters must be changed on a regular basis If you notice a reduction in air flow f...

Страница 6: ...ncy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UVC Lamps PCO Filter and Final Filter 1 To change...

Страница 7: ...ced UVC Lamp PCO Maintenance Kit DM900 1002 Contains 2 UVC lamps 2 lamp support clips 1 PCO filter and gloves Complete 2 Year Maintenance Kit DM900 1003 Contains 1 HEPA filter 4 carbon prefilters 2 UV...

Страница 8: ...All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warran...

Отзывы: