REMOTE CONTROL

 

 

The air conditioner can be controlled with the remote control. Two AAA-batteries are required to use the 

remote control.  

 

 

 

1. 

POWER

:

 Press the POWER button to turn the machine

 

on or off.  

 

2. 

TIMER

:

 Press the TIMER button to set the timer. 

 

3. 

DOWN

:

 Press the DOWN button to decrease the desired temperature or 

timer 

 

4. 

MODE

:

 Press the MODE button to switch between cooling, fan and dry 

modes. 

 

5. 

UP

:

 Press the UP button to increase the desired temperature or timer 

 

6. 

FAN

:

 Press the FAN button to change between high and low fan speeds. 

 

7. 

SLEEP MODE

:

 Press the SLEEP button to turn on the sleep mode 

 

  

 

 

 

 

 

 

MULTI PROTECTIVE FUNCTIONS 

 

 

ANTI-FREEZING PROTECTING CONTROL  

When the ambient temperature is low while in Cooling Mode, the compressor and water motor will stop 

working.  If  the  copper  coil  temperature  reaches  <  2⁰C  for  over  20  seconds.  When  the  copper  coil 
temperature increases to >8⁰C, the protection will be stopped. 

 

 

 

WATER-FULL PROTECTION: 

 

When the water level in the internal water tank reaches the maximum level, the unit will sound an alarm 
and the tank full light will illuminate. Please drain the water from the internal water tank by removing the 
rubber stopper. 

 

 

 

COMPRESSOR DELAY-PROTECTION 

 

 

The compressor runs a 3 minute delay protection function. 

 

 

 

 

COMPRESSOR PROTECTION  

In cooling and dry modes, if the temperature difference between the coil temperature and room 
temperature is less than 3⁰C, for more than 30 minutes, the machine will enter the ‘no refrigerant’ 
compressor protection mode. The compressor and water spring motor will stop working. The up 
fan runs at low speed and the down fan stops running  

 

 

 

Содержание SILENT10

Страница 1: ...NDITIONER Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for our enti...

Страница 2: ...TIONS 3 FEATURES 5 PARTS LIST 5 INSTALLATION 6 OPERATION 8 REMOTE CONTROL 9 EMPTYING THE INTERNAL WATER TANK 10 MANUAL DRAINAGE 10 MAINTENANCE 11 CLEANING 11 END OF SEASON MAINTENANCE 11 TROUBLESHOOTI...

Страница 3: ...ed with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be...

Страница 4: ...carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must fol...

Страница 5: ...xury model Bright LED screen indicates temperature and operation mode On Off timer function allows you to choose when the unit operates Compressor protection technology PARTS LIST ACCESSORIES 1 Extend...

Страница 6: ...e hose and screw into the exhaust connector At least 3 full turns 3 Push the Exhaust Connector onto the Exhaust outlet on the rear of the unit 4 Make sure the unit is upright and there are no obstruct...

Страница 7: ...air from your room while efficiently cooling it Your air conditioner should be used without the vent pipe in dry mode When using dry mode ensure that an external water tank is used monitored and regul...

Страница 8: ...of hours POWER OFF TIMER With the appliance running with the desired settings press the TIMER button to setup the power off timer Press the UP and DOWN buttons to adjust the duration of the timer fro...

Страница 9: ...hile in Cooling Mode the compressor and water motor will stop working If the copper coil temperature reaches 2 C for over 20 seconds When the copper coil temperature increases to 8 C the protection wi...

Страница 10: ...drain from the internal tank Put the rubber stopper back into place CONTINUOUS DRAINAGE Remove the rubber stopper from the continuous drainage port Connect a water pipe to the water outlet You can plu...

Страница 11: ...warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean CLEAN THE LOWER FILTER SCREEN FRAME Hold the handle of the air inlet filter screen frame and pull it outward...

Страница 12: ...user manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat pr...

Страница 13: ...te when depositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL SILENT10 V3 SILENT10E V3 Capacity Cooling 2 64kWh 9...

Страница 14: ...te the online form 0871 620 1057 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...

Отзывы: