REMOTE CONTROL
The air conditioner can be controlled with the remote control. Two AAA-batteries are required to use the
remote control.
1.
POWER
:
Press the POWER button to turn the machine
on or off.
2.
TIMER
:
Press the TIMER button to set the timer.
3.
DOWN
:
Press the DOWN button to decrease the desired temperature or
timer
4.
MODE
:
Press the MODE button to switch between cooling, fan and dry
modes.
5.
UP
:
Press the UP button to increase the desired temperature or timer
6.
FAN
:
Press the FAN button to change between high and low fan speeds.
7.
SLEEP MODE
:
Press the SLEEP button to turn on the sleep mode
MULTI PROTECTIVE FUNCTIONS
ANTI-FREEZING PROTECTING CONTROL
When the ambient temperature is low while in Cooling Mode, the compressor and water motor will stop
working. If the copper coil temperature reaches < 2⁰C for over 20 seconds. When the copper coil
temperature increases to >8⁰C, the protection will be stopped.
WATER-FULL PROTECTION:
When the water level in the internal water tank reaches the maximum level, the unit will sound an alarm
and the tank full light will illuminate. Please drain the water from the internal water tank by removing the
rubber stopper.
COMPRESSOR DELAY-PROTECTION
The compressor runs a 3 minute delay protection function.
COMPRESSOR PROTECTION
In cooling and dry modes, if the temperature difference between the coil temperature and room
temperature is less than 3⁰C, for more than 30 minutes, the machine will enter the ‘no refrigerant’
compressor protection mode. The compressor and water spring motor will stop working. The up