background image

Page 8 of 13 

Sleep Mode: 

In the cooling Mode, Press the “UP” and 

“FAN”

 buttons together to turn on the sleep mode, then the unit 

will work on Energy-Saving and lowest fan mode. 

 
Note: The sleep mode is not operational in dehumidifying or Fan mode. Please use the remote control to 
set the sleep mode, it cannot be set from the air con touch control panel. 

 

2.

 

Operating Instructions of the Remote Control 

2.1

 

Power: Press the 

key to turn on or off the machine

 

2.2

 

Mode: press the 

  key to switch between cooling, fan, 

dehumidification and heating mode (optional) 

2.3

 

Up: press the 

key to increase temperature and timer set value   

2.4

 

Down: press the

  key to reduce temperature and timer set value   

2.5

 

Fan: press the

  key to cycle between high, medium and low fan speed 

2.6

 

Timer: press the

  key to set timer value 

2.7

 

Cleaning: Press the

  key to stops the compressor working after turning 

off the unit, but the fan will continue to work for 3 minutes to dry off the   
the evaporator reducing the mould and bacterial grow 

2.8

 

Press the key

  to switch between Celsius and Fahrenheit   

2.9

 

Sleep Mode: Press the

  key to turn on the sleep mode. 

 
 

3.

 

Multi protective function     

 

3.1. Frost Protection Function:   

In cooling, dehumidification or economic power saving mode, if the temperature of the exhaust pipe is too 
low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to 
a certain temperature, it can automatically revert to normal operation.   
 

3.2. Overflow Protection Function: 

When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, 
and the LDC temperature display area will show "FL". At this point, you need to move the drainage pipe 
connecting the machine or the water outlet to sewer or other drainage area to empty the water (details 
see Drainage Instructions at the end of this chapter). After the water is emptied, the machine will 
automatically return to the original state.   

 
3.3. Automatic Defrosting (heating and cooling models have this function):   

The machine has automatic defrosting function: during defrosting, heating symbol on the display screen will 
flash. 

 
3.4. Automatic Thermal Protection: 

To protect the service life of the machine, the machine has automatic thermal protection in heating mode. 
During the protection period, the compressor and the lower motor will stop operation and will automatically 
return to normal heating state after the temperature of the machine recovers. 

 
3.5. Protection Function of the Compressor   

To increase the service life of the compressor, it has a 3-minute delay booting protection function after the 

Содержание SILENT 12

Страница 1: ...ONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for o...

Страница 2: ...Page 2 of 13 SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 4 INSTALLATION 5 OPERATION AND SETTINGS 7 WATER DRAINAGE 9 MAINTENANCE 10 TROUBLESHOOTING 11 APPENDIX 12 TECHNICAL DATA 12...

Страница 3: ...damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by a...

Страница 4: ...Self evaporative system no external water tank needed Designer inspired luxury model LED screen indicates temperature and operation mode On Off timer function allows you to choose when the unit operat...

Страница 5: ...ssemble the exhaust hose to the air conditioner body Extend one head of the hose and screw it into the unit anti clockwise The hose can be removed by screwing the hose clockwise Note to screw it into...

Страница 6: ...ooling mode ensure that the opening left is as small as possible The best form of installation is through a wall duct By properly venting you expel hot air from your room while efficiently cooling it...

Страница 7: ...e UP 3 and DOWN 5 button set temperature and timer In cooling mode the temperature can range from 16 31 Timer is 1 24 hrs Pressing UP and DOWN buttons simultaneously shifts between and FAN button 2 a...

Страница 8: ...or economic power saving mode if the temperature of the exhaust pipe is too low the machine will automatically enter protection status if the temperature of the exhaust pipe rises to a certain temper...

Страница 9: ...e water rubber stopper back and screw the drain 1 6 Plug cap back into place 2 Continuous drainage 2 1 Screw off the drain plug cap and unplug the water rubber stopper 2 2 Use a water pipe to connect...

Страница 10: ...or filter screen into warm water with neutral detergent about 40 104 and dry it in the shade after rinsing clean B Clean the lower filter screen frame a Hold the handle of the air inlet filter screen...

Страница 11: ...ere are other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions B...

Страница 12: ...ase be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centers TECHNICAL DATA Capacity 3 52KWh 12 000BTU Rated Input 1 3...

Страница 13: ...1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if...