PRODUCT FICHE  

Model Identifier: EPMH1000LED 

Item 

Symbol 

Value 

Unit 

  Item 

Unit 

Heat Output 

  Type of heat input, for electric storage local 

space heaters only (select one) 

Nominal heat 

output 

P

nom 

1.0 

kW 

  manual heat charge control, with 

integrated thermostat 

No 

Minimal heat 

output 

P

min 

kW 

  manual heat charge control with room 

and/or outdoor temperature feedback 

No 

Maximum 

continuous 
heat output 

P

max 

1.0 

kW 

  electronic heat charge control with room 

and/or outdoor temperature feedback 

No 

Auxiliary electricity consumption 

  fan assisted heat output 

No 

At nominal 

heat output 

el

max

 

N/A 

kW 

 

Type of heat output/room temperature control 

(select one) 

At minimum 

heat output 

el

min

 

N/A 

kW 

  single stage heat output and no room 

temperature control  

No 

In standby 

mode 

el

SB

 

  two or more manual stages, no room 

temperature control 

No 

 

 

 

 

  with mechanical thermostat room 

temperature control 

No 

 

 

 

 

  with electronic room temperature control 

No 

 

 

 

 

  with electronic room temperature control 

plus day timer 

No 

 

 

 

 

  with electronic room temperature control 

plus week timer 

Yes 

 

 

 

 

 

Other control options (multiple selections 

possible) 

 

 

 

 

  room temperature control with presence 

detection 

No 

 

 

 

 

  room temperature control, with open 

window detection 

No 

 

 

 

 

  with distance control option 

No 

 

 

 

 

  with adaptive start control 

Yes 

 

 

 

 

  with working time limitation 

Yes 

 

 

 

 

  with black bulb sensor 

No 

Contact 

Details 

electriQ, Unit J6, Lowfields Business Park, Lowfields Way, Elland, 
West Yorkshire, HX5 9DA

 

 

Содержание EPMH1000LED

Страница 1: ...0LED Thank you for choosing electriQ Please read the manual before using this heater and keep it safe for future reference Visit our page www electriQ co uk for our entire product range THIS PRODUCT IS ONLY SUITABLE FOR WELL INSULATED SPACES OR OCCASIONAL USE ...

Страница 2: ...2 CONTENTS SAFETY 3 PRODUCT OVERVIEW 5 INSTALLATION 5 CONTROL PANEL 7 OPERATION 8 CLEANING AND STORAGE 10 TECHNICAL SPECIFICATIONS 10 TROUBLESHOOTING 10 SUPPORT 11 PRODUCT FICHE 12 ...

Страница 3: ...ce provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate or clean the appliance or perform user maintenance Children under 3 years should be kept away unles...

Страница 4: ...as hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or any flammable liquids are used or stored Never locate this appliance where it may fall into a bathtub or otherwise become exposed to water This appliance is IP24 rated and so can be used or installed within a bathroom as long as the appliance and its cables are not within Zones 0 2 If used within a bathroom t...

Страница 5: ...unted FITTING THE LEGS Unscrew the two screws holding the wall mounting bracket to the back of the body and keep in a safe place to allow the option of wall mounting in the future Attach the legs by securing them to the base of the heater using the screws provided Once the legs are attached slot the supplied castors into the holes until they fully engage Castors Display Control Panel ...

Страница 6: ... in position on the wall using a spirit level to ensure it is straight Mark the position of the mounting holes using a Pencil Drill the holes at the marked position using a suitable drill bit Insert the wall plugs into the holes before fixing the bracket to the wall using the supplied screws Ensure that the bracket is secure Fit the heater into the wall bracket ensuring it is correctly positioned ...

Страница 7: ...emperature Up Timer Open Temperature Down Timer Close Mode Selection and Hour Button Function Selection and Weekly Button Heat Level Selection Child Lock Temperature Up Timer Open Temperature Down Timer Close Mode Selection and Hour Button Function Selection and Weekly Button ...

Страница 8: ...te VALUE Press and hold the SET button to set the day HEAT LEVEL Press the HEAT LEVEL button to change between high heat setting and low heat options Low Heat High Heat TEMPERATURE Use the UP and DOWN buttons to adjust the desired temperature Range of 5 40 C The display shows the current temperature on the left and the desired toom temperature on the right CHILD LOCK Press and hold the HEAT button...

Страница 9: ...ll be operational for each of the days in the above heating period Use the UP button to set a start time and the DOWN button button to set the stop time While the unit is operating under the weekly timer it will heat up to the temperature set within the ON mode Notes When the room temperature reaches the desired level the heater will change to Low Heat mode When room temperature is 2 degrees over ...

Страница 10: ... invalidate the warranty and may cause bodily harm Issue Possible Reason Solution No power 1 Power cord is unconnected 2 There is no power from socket 3 The power switch on the rear of the unit is turned off 1 Connect the power cord 2 Check socket is turned on 3 Ensure the power switch on the rear of the unit is in the on position Odour emission from unit 1 New unit When the unit is used for the f...

Страница 11: ...ields Way Elland West Yorkshire HX5 9DA Disposal Do not dispose this product as unsorted municipal waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating civic amenity sites r...

Страница 12: ...temperature control select one At minimum heat output elmin N A kW single stage heat output and no room temperature control No In standby mode elSB 0 W two or more manual stages no room temperature control No with mechanical thermostat room temperature control No with electronic room temperature control No with electronic room temperature control plus day timer No with electronic room temperature ...

Отзывы: