background image

 

  The air must not be discharged into a flue that is used for exhausting fumes 

from appliances burning gas or other fuels. 

  When the hood is vented externally and used with appliances which burn 

fuel (e.g. gas, oil, wood) the area must be sufficiently ventilated to ensure 
safe operation. Fresh air must be allowed to freely enter the room to prevent 
a partial vacuum. 

  A partial vacuum can starve the heating appliance of oxygen, impairing 

combustion.    It can also prevent toxic fumes from leaving the room, or can 
cause fumes to be sucked into the room from outside.   

  Safe operation is only possible when the partial vacuum within the working 

area does not exceed 4 Pa (0.04 mbar).    This can be achieved by ensuring 
air is able to enter the room from outside through a suitable sized opening 
which cannot be sealed during operation. A number of alternative solutions 
are available to ensure this.    If in any doubt, professional advice should be 
sought. 

  Regulations concerning the discharge of air have to be fulfilled. 

  There is a potential fire risk if cleaning is not carried out in accordance with 

the instructions. 

  Clean your appliance periodically by following the method given in the 

chapter MAINTENANCE 

  If used in recirculation mode, the charcoal filters trap odours and must be 

replaced at least once a year depending on how frequently the cooker hood 
has been used. 

  For safety reasons, please use only the same size of fixing or mounting 

screw, which are recommended in this instruction manual. 

  Warning: Failure to install the screws or fixing device in accordance with 

these instructions may result in electrical hazards 

 

CAUTION: Accessible parts of the hood can become very hot during 

use with cooking appliances, whether in use or not, due to heat rising 
from the hob. Sufficient time should be allowed for the unit to cool 
before touching either the housing or the grease filters 

 

Содержание eiQCHB60B

Страница 1: ...ng your electriQ cooker hood This instruction manual is designed to provide you with all required instructions related to the installation use and maintenance of the appliance In order to operate the...

Страница 2: ...OPTIONS FOR VENTILATION 5 UNPACKING YOUR APPLIANCE 5 PRODUCT OVERVIEW 6 DIAGRAM 7 INSTALLATION 8 OPERATION 12 MAINTENANCE 14 CARBON FILTERS OPTIONAL 14 LIGHT BULB REPLACEMENT 15 TROUBLESHOOTING 15 TEC...

Страница 3: ...cessary The extraction fan must be level to avoid grease collection at one end as this could cause a potential fire risk Do not leave frying pans unattended during use because overheated fat or oils m...

Страница 4: ...ternative solutions are available to ensure this If in any doubt professional advice should be sought Regulations concerning the discharge of air have to be fulfilled There is a potential fire risk if...

Страница 5: ...n of air once it has passed through the filters The filtered air is then expelled through the vent holes in the side of the chimney When setting the unit up in this configuration carbon filters should...

Страница 6: ...ERVIEW PARTS SUPPLIED Description Illustration Qty Cooker hood 1 Chimney 2 Exhaust Pipe 1 Adaptor 1 cable tie 1 Plate I 1 Plate II 1 Screw 4mm x 40mm 4 Wall plug 8 Screw 4mm x 8mm 6 Screw 4mm x 30mm 4...

Страница 7: ...7 DIAGRAMS eiQCHB60B eiQCHB90B...

Страница 8: ...Screws 4mm x30mm into position to hang the hood ensuring the heads are protruding by 3 4mm screw and tighten Plate II onto the wall with the screws 4mm x 40mm and wall plugs provided 5 The 2 x airflap...

Страница 9: ...length of the chimney to around the required height Fine adjustment can be done later Then install plate I on the chimney using two screws 4mm x 8mm Only tighten the screws loosely to allow the chimne...

Страница 10: ...ons and make sure that the voltage V and the frequency Hz indicated on the identification plate found inside the cooker hood and all the data inside the appliance are exactly the same as the voltage a...

Страница 11: ...below Put the activated carbon filter onto the end of the motor unit and turn it in anti clockwise direction Repeat the same on the other side see diagram NOTES Make sure the filter is securely locked...

Страница 12: ...press the TIMER button and the display will show the previously used timer duration or 05 00 to indicate 5 minutes if the timer has not been previously used Use the SPEED button to increase the timer...

Страница 13: ...running press the button to increase the fan speed TURN OFF DECREASE FAN SPEED While the fan is running at high or medium speed press the button to decrease the fan speed While the fan is running at l...

Страница 14: ...r as shown in the Installation section Clean it with a soft nylon brush in a mild solution of warm water and a small amount of washing up liquid Washing up liquid alone should not be used After cleani...

Страница 15: ...ge range AC 220 240V Dimensions TROUBLESHOOTING Fault Cause Solution Light on but fan does not work The fan blade is jammed Switch off the unit Repair to be carried out by qualified service personnel...

Страница 16: ...2 2 W Nominal power of the lighting system WL 6 0 W Average illumination of the lighting system on the cooking surface Emiddle 306 lux Measured power consumption on standby mode PS 0 37 W Measured pow...

Страница 17: ...ciency point PBEP 370 Pa Maximum airflow at boost position Qmax 836 4 m3 h Maximum airflow Qmax 632 1 m3 h Measured electric power input at best efficiency point WBEP 223 1 W Nominal power of the ligh...

Страница 18: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...