ElectrIQ eiQ60PBSLIMEN Скачать руководство пользователя страница 9

 

 

INSTALLATION  

 

 

 

 

 

 

 

 

 

 

 

 

• 

Draw a vertical line up to the ceiling or up to the upper limit, at the centre of the area in 
which the hood is to be fitted.  

 

• 

A horizontal line 

A

 at 

790

– 890

 mm above the cooker top. 

 

• 

A horizontal line 

B

 at a 

X

 mm above the horizontal line 

A

 

• 

A horizontal line 

C

 at a 115mm below the horizontal line 

A.

 

• 

Mark a point 

(1)

 on the horizontal line 

A

80

 mm to the vertical reference line.

 

• 

Repeat this operation on the other side, checking that the two marks are levelled.

 

• 

Mark a point 

(2)

 on the horizontal line 

B

60

 mm to the vertical reference line.

 

• 

Repeat this operation on the other side, checking that the two marks are on the same 
horizontal line.

 

• 

Mark a point 

(3)

 on the horizontal line 

C

150

 mm to the vertical reference line. Repeat this 

operation on the other side, checking that the two marks are levelled.

 

FIX THE BRACKETS 

• 

Drill holes at the marked points with a 

ɸ10 mm drill bit.

 

• 

Insert the Wall Plugs 11 into the holes.

 

• 

Fix a Chimney fixing bracket 

21

 with 2 screws 

10

 (5 x 50) at the 

horizontal line B. 

Screw 2 screws 

10 

(5 x 50) to Wall Plugs 

11 

at the 

horizontal line 

A

; approximately the four fifth length of the screws 

10

 

(5 x 50) was screwed into the Wall Plugs 

11, 

used for hook the 

hood.

 

 
LOWER DECORATIVE CHIMNEY 

 

• 

Fix the exhaust pipe on the hood body, connect chimney and hood body with 2 screws 

12

connect chimney fixing bracket and chimney with 2 screws 

12

.

 

Содержание eiQ60PBSLIMEN

Страница 1: ...OOD eiQ60PBSLIMEN eiQ90PBSLIMEN Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electriQ co uk for our e...

Страница 2: ...IEW 5 PARTS LIST 6 INSTALLATION 7 V FLAP INSTALLATION 7 OPTIONS FOR VENTILATION 8 INSTALLING THE UNIT 9 OPERATION 10 FILTER INFORMATION 11 BULB REPLACEMENT 12 CLEANING AND MAINTENANCE 12 TROUBLESHOOTI...

Страница 3: ...rheated fat or oils might catch fire If the cooker hood is damaged do not attempt to use it If the supply cord is damaged it must be replaced by the manufacturer its service agent or a similarly quali...

Страница 4: ...otential fire risk if cleaning is not carried out in accordance with the instructions Clean your appliance periodically by following the method given in the chapter MAINTENANCE If used in recirculatio...

Страница 5: ...5 PRODUCT OVERVIEW...

Страница 6: ...1 1 Hood Body 2 1 1 Lower decorative chimney 2 2 1 Upper decorative chimney 3 1 V flap 4 1 Exhaust pipe Not included 5 1 Charcoal filter 6 6 Screws 4 2 x 9 5 Screws 4x8 7 7 Wall Plugs 8 2 Chimney fix...

Страница 7: ...dy The images only show an example of how to mount the V flap the outlet may be various according to different models and configuration To mount the V flap 1 you should 1 Mount two half parts 2 into t...

Страница 8: ...eans of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 1 Before installation turn the unit off and unplug it from the outlet 2 The cooker...

Страница 9: ...her side checking that the two marks are on the same horizontal line Mark a point 3 on the horizontal line C 150 mm to the vertical reference line Repeat this operation on the other side checking that...

Страница 10: ...the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe sho...

Страница 11: ...hs according to your cooking habit The installation procedure of activated carbon filter is as below Replacements are available from the retailer the hood was purchased from under reference eiqmidcar9...

Страница 12: ...embly take out the light plate assembly and pull out the light wire If the light wire cannot be pulled out it can be cut directly with scissors Apply the reverse procedure to install the light back MA...

Страница 13: ...ht does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch power outlet on Oil leakage One way valve and the outlet a...

Страница 14: ...M 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit y...

Страница 15: ...BEP 144 Pa Maximum air flow Qmax 342 0 m3 h Measured electric power input at best efficiency point WBEP 49 5 W Nominal power of the lighting system WL 1 5 1 W Measured power of the lighting system WL...