background image

10

Setting

the

Dehumidification

level

Start

the

unit

and

leave

it

for

5

Ͳ

10

minutes

on

sleep

mode

(50%RH)

until

the

humidistat

is

able

to

correctly

read

the

humidity

within

the

room.

Press

the

humidity

level

key

to

select

the

desired

humidistat

controls

from

continuous

operation

(CO)

to

40%

50%

60%

70%.

While

pressing

the

humidity

level

key

the

display

cycles

the

humidistat

set

range

for

this

unit

from

40%

through

50%

60%

70%

ba

ck

to

continuous

mode.

 

Intelligent

dehumidification

and

power

saving

Your

ElectrIQ

dehumidifier

features

an

intelligent

micro

CPU

that

ensure

maximum

water

extraction

with

minimum

power

use

for

the

selection

made.

The

unit

will

try

to

maintain

humidity

level

selected

in

the

room

by

turning

off

the

heating

element

when

the

desired

humidity

is

reached.

Note

that

according

to

the

space

where

the

unit

is

used,

obstacles

in

the

direct

flow,

extra

humidity

being

added

at

any

time,

settings

selected,

as

well

as

other

environmental

factors

the

results

may

vary.

 

OPERATIONAL

ADVICE

1.

Plug

to

power,

press

the

power

button

to

turn

Ͳ

on

the

machine;

press

the

power

button

again

to

turn

Ͳ

off

the

dehumidifier.

2.

Make

sure

water

Ͳ

tank

is

placed/

fitted

correctly.

If

the

water

tank

is

not

fitted/placed

correctly

the

'water

full'

light

will

flash

and

the

machine

will

not

operate.

3.

When

the

dehumidifier

first

starts,

default

humidity

setting

is

set

to

50%

RH.

4.

When

unplugging

from

the

wall

socket

use

one

hand

to

hold

the

plug

and

the

other

hand

against

socket

to

avoid

power

cord

damage.

WARNING

:

Using

poor

quality

sockets,

extensions

or

overloading

the

circuits

may

cause

damage

to

the

machine

or

may

start

a

fire.

5.

When

switching

OFF

the

machine,

do

not

simply

unplug

the

unit

from

the

socket

Ͳ

ensure

you

turn

off

the

machine

properly

and

have

allowed

it

to

complete

the

drying

cycle

(

wait

for

the

fan

to

stop),

before

unplugging.

Tilt

Protection

Your

ElectrIQ

dehumidifier

was

designed

with

safety

in

mind.

When

unit

is

tilted

it

will

be

shut

down

to

minimize

safety

risk

or

damage.

The

On

light

will

flash

red,

to

indicate

anti

tilt

protection

has

activated.

  

If

the

unit

has

been

tilted,

please

do

not

use

if

for

a

day

or

two

until

the

internals

are

completely

dried,

as

using

the

unit

after

it

has

been

tilted

could

result

in

a

short

circuit,

which

would

internally

damage

the

unit.

 

Consult

the

service

centre

if

in

any

doubts

Содержание EDD8L

Страница 1: ...ER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electrIQ co uk for our entire...

Страница 2: ...ions 3 Features 5 Parts 6 Control panel 6 Front humidity indicator 8 Operation 9 Operational Advice 10 Positioning 11 Water Drainage 11 Continuous Drainage 12 Care and Maintenance 13 FAQ 14 Troublesho...

Страница 3: ...the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified elect...

Страница 4: ...ccumulate Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall should be 20 cm an...

Страница 5: ...tract water from the environment The desiccant dehumidifiers are ideal both at standard and low temperatures working on ambient range of between 1 32 C ElectrIQ desiccant dehumidifiers are light and e...

Страница 6: ...unit to turn off once pressed Humidity Timer Display Window Displays the current Humidity of the room When Humidity button pressed Shows desired humidity of room before reverting back to showing the c...

Страница 7: ...e energy savings while maintaining the set humidity Laundry Mode This mode is ideal for creating a great environment for drying clothes The unit will work for 8 hours continuously with the desired hum...

Страница 8: ...ion Mode This mode runs the fan without dehumidifying the air This is great for purifying the air when the desired room humidity has been reached especially when the optional HEPA filter is installed...

Страница 9: ...towards the clothes airer or hanging clothes Hot dry air comes from a 45 degrees angle Laundry mode can be used in conjunction with the stopping timer IMPORTANT Please follow the distances shown on th...

Страница 10: ...s the power button again to turn off the dehumidifier 2 Make sure water tank is placed fitted correctly If the water tank is not fitted placed correctly the water full light will flash and the machine...

Страница 11: ...ving it to a more central location at a later date For the most effective use run your dehumidifier with any external doors and windows kept closed Please note the unit should not be placed directly a...

Страница 12: ...nit CONTINUOUS DRAINAGE This dehumidifier has a continuous drain hole that can be connected to a plastic pipe with an 11 mm inner diameter Not Supplied Water can be automatically plumbed in or drained...

Страница 13: ...ush 3 If dirt and grease is accumulated wash the mesh filter in hot soapy water 3 Replace the filters in position as shown in the diagram Note Never use the unit without the antibacterial mesh dust fi...

Страница 14: ...ilding materials and new furniture and then when the desiccant is heated the smell is discharged back into the room This smell has been described as being like a burning or acrid smell It is normal wi...

Страница 15: ...ion process This is normal and helpful especially in the cold weather a dehumidifier is not an air cooler You may be used with a compressor dehumidifier which may blow also cold air Knocking noise com...

Страница 16: ...SLEEP 385 W Heating element 650W Max Airflow 200m3 hr 180m3 hr with optional HEPA Filter Timer 1 24 hours Working Temperature 1 32 C Noise 48 dB Water tank Capacity 5L Net Weight 7 5Kg Body Size 511...

Отзывы: