ElectrIQ CD12P Скачать руководство пользователя страница 13

TANK FULL LIGHT

When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, 

the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it 

correctly to resume operation.

AUTO DEFROST

When frost builds up on the evaporator coils, the compressor will cycle off and the unit will 

go in to defrost mode. Following completion of the defrost mode, the unit will return to the 

previously operating settings.

AUTO-RESTART (on some models)

If the unit stops unexpectedly due to the power cut, it will restart with the previous function 

selected automatically when the power resumes, and the 3 minute compressor protection 

has elapsed.

POWER

After the unit has stopped, to protect the compressor it is not recommended to resume 

operation for at least 10 minutes. Operation can resume after this period lapses. When the 

unit is restarted there is a 3 minutes delay before compressor will start.

LIGHTWEIGHT PORTABLE DESIGN ON CASTORS

The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit 

make it easy to move from room to room.

Your dehumidifier contains an advanced micro-CPU controlled device which is capable of 

self-diagnostics. The LCD display may also show the error and protections codes.

HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION

OTHER FEATURES AND INDICATORS

When the unit is running in a room with a temperature between 5

o

C and 12

o

C, it will enter 

defrost mode roughly every 30 minutes.

When the unit is running in a room with a temperature between 12

o

C  and 20

o

C, it will enter 

the defrost mode roughly every 45 minutes.

When the humidity of the room is 2% lower than the desired humidity the compressor will 

turn off automatically but the fan will continue to operate to ensure that the air within the 

room is not stale. The unit will use only a minimal amount of energy in fan mode.

When the humidity of the room is equal to or higher than the desired humidity the 

compressor will restart after a 3 minutes delay to protect the compressor.

• 

• 

10

09

Содержание CD12P

Страница 1: ...DIGITAL HUMIDISTAT CD12P Thank you for choosing electriQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electriQ co uk...

Страница 2: ......

Страница 3: ...CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Страница 4: ......

Страница 5: ...r outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power adapter or plug is damaged Ensure the power cord is not stretched or exposed...

Страница 6: ...frigerant system should not be perforated or punctured Do not place the unit next to heat sources e g electrical fires fireplaces etc Avoid mishandling the dehumidifier Dropping throwing the unit can...

Страница 7: ...dren may be left unattended If an extension lead may become overloaded Where the power cable may be damaged On a slope or uneven surface Where there is risk of fire or close to a naked flame Where it...

Страница 8: ...ed to extract unwanted humidity while saving money due to their power saving logic They feature an intelligent humidistat where the desired relative humidity can be adjusted in increments of 5 between...

Страница 9: ...IONAL ACCESSORIES HEPA Filter Activated carbon filter 06 Air inlet Water tank Pre filter activated Carbon filter Continuous Drain Port Power cord Air outlet Humidity indicator light Control Panel Hand...

Страница 10: ...op until the water tank is full HUMIDITY INDICATOR LIGHT HUMIDITY INDICATOR MODE When the appliance is started the indicator light will turn on automatically The indicator light colour will change acc...

Страница 11: ...POWER OFF FUNCTION While the appliance is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 1 24 hour...

Страница 12: ...is processed and the humidity is correctly measured To allow more moisture in the air press the up button and set to a higher desired humidity e g 60 70 We recommend setting the humidity to 50 55 This...

Страница 13: ...ressor will start LIGHTWEIGHT PORTABLE DESIGN ON CASTORS The dehumidifier is built to be compact and lightweight The castors on the bottom of the unit make it easy to move from room to room Your dehum...

Страница 14: ...entral and clear location so that it can draw this moist air towards it from all over the home A warm hallway or landing is an excellent position for your dehumidifier If possible leave interior doors...

Страница 15: ...way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The w...

Страница 16: ...em and hoover gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When...

Страница 17: ...k float and make sure tank is properly inserted in unit Front louvres do not open Louvre motor is blocked Check if anything is blocking the louvre Try to move gently the louvres up and down while the...

Страница 18: ...WP 3 DDisposal Do not dispose this product as unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all custom...

Страница 19: ...t plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guid...

Страница 20: ......

Отзывы: