SAFETY INSTRUCTIONS 

 

Important! 

 

• 

Carefully read the instructions before operating the unit

 

• 

This appliance is for indoor use only.

 

• 

Rating: This unit must be only connected to a 220-240 V / 50 Hz 
earthed outlet.

 

• 

Installation must be in accordance with regulations of the country where the unit is used.

 

• 

If you are in any doubt about the suitability of your electrical supply have it checked and, 
if necessary, modified by a qualified electrician.

 

• 

This air conditioner has been tested and is safe to use. However, as with any electrical 
appliance - use it with care.

 

• 

Disconnect the power from the appliance before dismantling, assembling or cleaning.

 

• 

Avoid touching any moving parts of the appliance.

 

• 

Never insert fingers, pencils or any other objects though the guard.

 

• 

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities. It is also not intended for use by those with a 
lack of experience and knowledge, unless they have been given supervision or instruction 
concerning the use of the appliance by a person responsible for their safety.

 

• 

Do not leave children unsupervised with this appliance.

 

• 

Do not clean the unit by spraying it or immersing it in water.

 

• 

Never connect the unit to an electrical outlet using an extension cord. If an outlet is not 
available, one should be installed by a qualified electrician.

 

• 

Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not 
stretched or exposed to sharp objects/edges.

 

• 

A damaged supply cord should be replaced by the manufacturer or a qualified electrician 
in order to avoid a hazard.

 

• 

Any service other than regular cleaning or filter replacement should be performed by an 
authorised service representative. Failure to comply could result in a voided warranty.

 

• 

Do not use the appliance for any purpose other than its intended use.

 

• 

The air conditioner unit must always be stored and transported upright, otherwise 
irreparable damage may be caused to the compressor; if in doubt we suggest waiting at 
least 24 hours before starting the unit.

 

• 

Do not move the air conditioner while it is operating. When operating the castors should 
be locked in position. 

• 

Ensure the unit is positioned so that it is on a flat level surface, and does not cause an 
obstruction to walkways. 

• 

This air conditioner is not designed to be used on boats, or any other type of 
transportation. 

• 

Avoid restarting the air conditioning unit unless 3 minutes have passed since being 
turned off. This prevents damage to the compressor.

 

Содержание A1/CMAC10M

Страница 1: ...AIR CONDITIONER CMAC10M Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co...

Страница 2: ...NTENTS SAFETY INFORMATION 3 FEATURES 5 APPLIANCE DIAGRAM 5 INSTALLATION 6 OPERATION 7 EMPTYING THE INTERNAL WATER TANK 8 CLEANING AND MAINTENANCE 8 TROUBLESHOOTING 9 SUPPORT 10 TECHNICAL SPECIFICATION...

Страница 3: ...the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electricia...

Страница 4: ...Do not use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system Any repairs or maintenance must only be carried out on...

Страница 5: ...ration Castors for Enhanced Portability Durable metal casing HOSE SPECIFICATIONS Hose Hose External Diameter mm Supplied Hose Length Max Permitted Hose Length cm Cold Air 120 37 200 Hot Air 160 37 300...

Страница 6: ...e NOTES The best form of installation is through a wall duct By properly venting you expel hot air from your room while efficiently cooling it IMPORTANT SAFEGUARDS If hoses are extended above the perm...

Страница 7: ...ndicator will illuminate To resume operation empty the internal water tank After the water is emptied the machine will automatically return to the original state AUTO DEFROST The machine has automatic...

Страница 8: ...the water tank If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated Please do not use continuous drainage if you intend to use the self...

Страница 9: ...manual and hose is not bent Loud Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat protect...

Страница 10: ...is full Office hours 9AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Lowfields Way Elland West Yorkshire HX5 9DA TECHNICAL DATA Model CMAC10M Cooling capacity 9 200 BTU Inp...