Electric Cooktops
EW36EC55G S, EW36EC55G B
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
EW36EC55G 09/12
© 2012 Electrolux Home Products, Inc.
4" x 8" opening to
route armoured cable
if base is present
Plywood base
(optional)
9" min.
25" min.
36"
13"
max.
cabinet
depth
18"
min.
30" min.
for
unprotected
cabinet
24" min.
for
protected
surface
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
24"
2" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
2
1
/
2
" min. from
edge of cutout to front
edge of countertop
20
3
/
8
" min.
20
5
/
8
" max.
35
3
/
4
" min.
36" max.
34
5
/
8
"
19
1
/
4
"
36
3
/
4
"
21
3
/
4
"
7"
3
1
/
8
"
Cooktop
Countertop
Countertop
7"
3
1
/
2
"
7
1
/
2
"
Front
Rear
Side View
3
1
/
8
"
36" Electric Touch-Control Cooktop Specifications
•
Product Weight – 58 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit fused
on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts = 9.9 / 7.4 kW
•
Amps @ 240 / 208 Volts = 41.3 / 35.6 Amps
•
Recommended Circuit Breaker – 40 Amps
•
Always consult local and national electric codes.
•
Allow 2" space beneath cooktop or optional platform to clear electrical
cable and allow space for installation of junction box on wall at back of
cooktop. Position center of junction box 10" inward from right side of
cooktop cutout, and 12" down from underside of countertop.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36".
•
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
•
Allow 2" minimum clearance between rear edge of cutout and nearest
combustible surface above countertop.
•
Allow 7-1/2" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
•
Installation of drawers beneath cooktop requires minimum 10"
clearance beneath countertop surface and assured clearance for
electrical connection.
•
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
•
Touch-Control Cooktop model EW36EC55G is approved to be used
over any Electrolux Electric Single Wall Oven.
(Refer to Electric Cooktop
Installation Over 30" / 27" Electric Single Wall Oven Specifications page
on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
Granite Countertop Installation Kit – (PN # 903061-9010).
•
Griddle Plate – (PN # 318251611).