© 2013 ELECTRIC MIRROR®

Luminaire

Disconnect

Chassis Knockout

Ground Push-In

Connector

Luminaire Disconnect

Neutral (White)

3) Wiring Details

Please note, all electrical installations should be carried out by a fully qualified

electrician in conformance with the National Electrical Code and local building codes.

4) Power Connection

Before proceeding to power supply  wiring, make sure the MC cable is brought in through the wall and

into the chassis knockout.

Insert ground wire in the grounded connector. Insert the power and neutral wires into the luminaire

disconnect. The power wire is inserted into the black port (number 1) and the neutral wire is

inserted into the white port (number 2).

Installation

1) Mounting chassis on the wall

Before mounting chassis on wall, identify mirror location on wall. Drill marks should be measured 

from the edge of the mirror 

NOT FROM EDGE OF CHASSIS

There are multiple mounting holes that can be chosen from to accommodate mounting locations. The 

chassis shall be installed with a minimum of (4) 1/4" x 1-1/2" lag screws or other engineering approved 

fasteners. Use wall anchors or reinforced backing areas to support chassis. See individual product 

specifications for mounting hole locations.

2) Install lamps.

Power (Black)