14
GB-031C/f.347
USER INSTRUCTIONS
R
F
P
CONTROL PANEL
Control Panel Key
A - Water pressure indicator (bar)
B - Water flow rate indicator (l/min)
C - kW indicator
D - Water temperature indicator (
0
C)
E - Digital display
F - Summer Mode
G - Call for Heat
H - Pump operation indicator
I - Return temperature flow indicator
J - Flow temperature indicator
K - Boiler heating indicator
INDICATORS
Heat Indicator
• ‘on’ – calling for heat
• ‘off’ – the required temperature has been reached – no call for heat is required
• Flickers – NA entry is open – (external boiler interrupt active)
P
Pump Indicator
• ‘on’ – pump is active, proper flow rate of water has been reached
• Flickers – lack of flow or insufficient flow rate of water – heating elements are off
Temperature Indicator
• Red light – Boiler is in heating mode
• Green light – Boiler temperature has been reached in radiators
A
Indicator flickers – water pressure is not sufficient (below 0.5 bar)
F
When boiler is in Summer Mode (i.e. switched off) indicator will blink
I
Indicator flickers – relative temperature sensor failure
J
Indicator flickers – relative temperature sensor failure
EE
Messages on electronic display – data record error
Dashes (- -) on display
– parameter out of range or a temperature sensor failure
Figure 13