KIT INSTALLATION.

 

Follow the steps below, in the described order.

   

STEP 1.

 Read the diagrams in this brochure and the technical manuals of the KIT (

VPM

VTx

SCU

).

   

STEP 2

. Make the electrical connections to the terminals (

ATM

VTM

VTE

) and then to the

 VPM

 outdoor panel.

   

STEP 3

Make the electrical connections of the 

LCK

 door lock and 

LOCK SUPPLY

 to the terminals of the 

SCU

 central unit 

and, if necessary, the connections to: the 

EXIT

 button; 

AUX

 additional installations; 

BAT

Vcam

 analog video camera.

   

STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRAL

SUPPLY UNIT!!!         DISCONNECT

 the fuses and make the 

L

,

N

,      connections to the 

SCU

        

CONNECT

 the fuses to the

power network. The        , 

S2

 LEDs turn on, and 

S1

 turns on only if the battery (12V/max. 42Ah) is connected.         

   STEP 5.1.

 

PROGRAMMING THE MAIN ENTRANCE PANEL

RFID CARDS/TAGs

         At the 

SCU

, long press (2-3 sec.) the 

PROG

              button (point 6). The 

PROG

 Red LED turns on         Go to the 

VPM

 panel from the main entrance and touch each 

              RFID CARD to the        (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues 

              two beeps. Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building 

              Return to the 

SCU

 and short press the 

PROG

 button. The Red LED turns off. The main panel keeps 

address 1

, which

              is set from the factory and is ready to function. 

  

 STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs.

 If the access in the building is 

made through two entrances, the 

VPM2

 additional panel (point 11) from entrance 2 must be set up with 

address 2

At 

SCU 2

 long press the 

PROG 

button. The 

PROG

 Red LED turns on.         At the 

VPM2

 panel, long touch the 

Fam.1

 key 

(long confirmation beep)

, then short touch the 

Fam.1

 key, twice. The panel confirms the storage of 

address 2

 with 

two short beeps. Continue programming the CARDS/TAGs in the 

VPM2

 panel.         Each touch of the CARD/TAG to the         area is

confirmed by the 

VPM2

 with two beeps.         Return to the 

SCU2

 and short press the 

PROG

 button. The Red LED turns off. 

The 

VPM2

 and 

VPM1

 panels are ready to function, with all the terminals in the building. 

   

STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL.

 The terminals keep 

Address 1

, which is set by the

manufacturer.

   

STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS.

 The terminals for 

Family 2

 will have 

address 2

, the terminals for 

Family 3

 will have 

address 3

 and so on for 

4

5

 etc.

   

Program the new addresses as follows

:        At 

SCU 1

 long press (3 sec.) the 

PROG

 button. The 

PROG

 Red LED turns on   

At the terminals for 

Family 2

, long touch the           key. The terminal confirms with one long beep. Short touch the              

key twice. Two short beeps are issued. The terminal stores 

address 2

. Continue programming 

address 3

 at 

Family 3

 following

the same steps. Long touch the          key and after the long beep, short touch the          key three times. Storage is confirmed

with three short beeps.         

Return to the 

SCU

 and short press the 

PROG

 button. The Red LED turns off.

 The terminals are ready

to function. 

RECOMMENDED CABLES 

(point 1, pg. 15) Maintain the same wire colors for the same connections.

2

Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm  – Green/Yellow) from the  

panel (VPM) to the         central unit (SCU).

1

DETAILED PRODUCT CODES

   

VPM - smart video outdoor panel

; Product codes: 

1Fam

.VPM.1S(F)R02.xxy04; 

2Fam

.VPM.2S(F)R02.xxy04; 

3Fam

.VPM.3S(F)R02.xxy04; 

5Fam

.VPM.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)

   

RFID access CARD/TAG

 (secured at reading and copying). They are stored and can be deleted from the VPM.

   

ATM - smart+ audio terminal

; Product code: ATM.0S402.xxy04

   

VTM

 

- smart+ 3.5” video terminal

; Product code: VTM.3S402.xxy04

   

VTM/VTE

 

- smart+/extra 7” video terminal

; Product codes: VTM.7S402.xxy04/ VTE.7S902.xxy04

   

VCB – Video connection box

 (1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04

EN

INSTALLATION INSTRUCTIONS –        VIDEO DOOR PHONE KIT

Thank you for choosing the 

ELECTRA

 products. We will assist you throughout the entire warranty period. 

For technical support and assistance you can contact us at ELECTRA Building Communications GmbH,        

           +43 1 810 20 99, [email protected].

2

1) Max.   75 ml         4 x 0.5 mm  

(H03VV-F4G 0.5) 

2

2) Max. 150 ml         4 x 0.75 mm  

(H05VV-F4G 0.75) 

3) Max. 250 ml         UTP cat5e (AWG24)

 

or

 

UTP cat6e (AWG23)

Содержание Touch Line Series

Страница 1: ...4 Wires 1 2 3 Families VIDEO DOOR PHONE KIT 3 5 7 User manual EN...

Страница 2: ...ls are ready to function with all the terminals in the building STEP 6 1 PROGRAMMING THE ADDRESS OF THE Fam 1 TERMINAL The terminals keep Address 1 which is set by the manufacturer STEP 6 2 PROGRAMMIN...

Страница 3: ...call keys are not backlighted The BAT and U LEDs are green At the SCU the VIDEO DOOR PANEL LED is red Check the continuity and the accuracy of the U and GND connections from the SCU to the panel 6 A t...

Страница 4: ...t6e AWG23 3 1 EN U C D GND 20 25mm 6mm Vin U C D GND 20 25mm 6mm Vout N F AC 110 230V EXIT EXIT LOCK SUPPLY LCK LCK DOOR LOCKS N F AC 110 230V FUSE T1 6A E307311 NO NC 2x6Aa c N L max 24 Va c 50Hz 60H...

Страница 5: ...Hz max 24 Vd c max 3 Ad c U C D GND Vin1 VIDEO DOOR PANEL N F AC 110 230V 6 A 3 5 sec max 24V 1A a c c c SCU OTHER VIDEO CAMERA S Vin2 AUX1 AUX2 BAT VPM SCU SCU N F AC 110 230V EXIT EXIT LOCK SUPPLY L...

Страница 6: ...1 Adr 1 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG SCU U PROG BAT 110 230V OUT1 U C D GND Vout Vcam EN LCK max 24Va c 24Vd c EXIT S1 2x6Aa c 110Va c 50Hz 230Va c 50Hz N L U C D GND Vin LOCK SUP...

Страница 7: ...BL2 Doorbell U C D GND Vin GONG Fam 1 Adr 1 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG OUT2 U C D GND Vout U C D GND Vout VPM Adr 1 Fam 2 EN LCK max 24Va c 24Vd c EXIT S1 2x6Aa c 110Va c 50Hz 2...

Страница 8: ...G Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 U C D GND Vout Vcam OUT2 OUT3 U C D GND Vout U C D GND Vout VPM Adr 1 GONG 2 GONG 1 DBL 1 DBL 2 Doorbell U C D GND Vin Fam 1 Adr 1 GONG EN AUX BAT max 42...

Страница 9: ...SCU U PROG BAT 110 230V OUT1 U C D GND Vout AUX Vcam Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 AUX Vcam VPM Adr 2 VTM 7S402 xxy04 VTE 7S902 xxy04 VTM 3S402 xxy04 ATM 0S402 xxy04 U C D GND Vout U C...

Страница 10: ...Environment Management System R The products contain UL compliant printed circuit boards ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante Spain ELECTRA products are registered as I...

Отзывы: