5-5
PERFORMANCE DATA & PRESSURE CURVES
SM CN 1-E.1 GB
5.2 CN
35
DCI
5.2.1
Cooling Capacity (kW) - Run Mode
[230V] : Indoor Fan at High Speed.
ID COIL ENTERING AIR DB/WB TEMPERATURE [C
0
]
OD COIL
ENTERING AIR DB
TEMPERATURE [
0
C]
DATA
22/15
24/17
27/19
29/21
32/23
-10 - 20
(protection range)
TC
80 - 110 % of nominal
SC
80 - 105 % of nominal
PI
25 - 50 % of nominal
25
TC
3.38
3.60
3.83
4.05
4.27
SC
2.40
2.45
2.50
2.55
2.60
PI
0.75
0.77
0.78
0.80
0.81
30
TC
3.22
3.44
3.66
3.88
4.11
SC
2.34
2.39
2.44
2.49
2.54
PI
0.84
0.86
0.87
0.89
0.90
35
TC
3.06
3.28
3.50
3.72
3.94
SC
2.28
2.33
2.38
2.43
2.48
PI
0.93
0.95
0.96
0.97
0.99
40
TC
2.89
3.12
3.34
3.56
3.78
SC
2.22
2.27
2.32
2.37
2.42
PI
1.02
1.03
1.05
1.06
1.08
46
TC
2.70
2.92
3.14
3.36
3.58
SC
2.15
2.20
2.25
2.30
2.34
PI
1.13
1.14
1.15
1.17
1.18
LEGEND
TC –
Total Cooling Capacity, kW
SC – Sensible
Capacity,
kW
PI –
Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.2.2 Capacity
Correction
Factor
Cooling Capacity Ratio Vs. Outdoor Temperature
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
20
25
30
35
40
45
Outdoor Temperature [ºC]
Cap
aci
ty
Rat
io
CONTENT
Содержание CN 25 DCI
Страница 15: ...4 2 OUTLINE DIMENSIONS SM CN 1 E 1 GB 4 2 Outdoor Unit DCI 50 4 3 Outdoor Unit DCI 60 CONTENT ...
Страница 16: ...4 3 OUTLINE DIMENSIONS SM CN 1 E 1 GB 4 4 Outdoor Unit DCI 72Z CONTENT ...
Страница 44: ...8 1 WIRING DIAGRAMS SM CN 1 E 1 GB 8 WIRING DIAGRAMS 8 1 CN 25 35 50 60 70 DCI CONTENT ...
Страница 90: ...13 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM CN 1 E 1 GB 13 9 Outdoor Unit ONG3 50 DCI CONTENT ...
Страница 92: ...13 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM CN 1 E 1 GB 13 11 Outdoor Unit DCI 60 CONTENT ...
Страница 94: ...13 14 EXPLODED VIEWS AND SPARE PARTS LISTS SM CN 1 E 1 GB 13 13 Outdoor Unit DCI 72Z CONTENT ...