5-1
PERFORMANCE DATA & PRESSURE CURVES
Revision Y05-01
Service Manual - ALPHA
5.
PERFORMANCE DATA & PRESSURE CURVES
5.1 Alpha7/CON7
5.1.1 Cooling
Capacity
(kW)
ENTERING AIR
DB OD Coil(
o
C)
Data
ENTERING AIR WB/DB ID Coil(
o
C)
15/21
17/24
19/27
21/29
23/32
15
(1)
TC
2.09 2.21 2.32 2.42 2.50
SC
1.47 1.56 1.64 1.60 1.63
PI
0.48 0.48 0.48 0.49 0.49
20
(1)
TC
2.07 2.19 2.30 2.40 2.48
SC
1.48 1.57 1.66 1.61 1.64
PI
0.52 0.52 0.53 0.53 0.53
25
TC
1.99 2.13 2.26 2.36 2.44
SC
1.43 1.53 1.62 1.59 1.63
PI
0.56 0.57 0.57 0.58 0.58
30
TC
1.87 2.01 2.17 2.26 2.34
SC
1.36 1.47 1.58 1.55 1.61
PI
0.61 0.62 0.62
0.63 0.63
35
TC
1.72 1.87
2.05
2.15 2.23
SC
1.28 1.39
1.52
1.50 1.56
PI
0.66 0.67
0.68
0.69 0.69
40
TC
1.56 1.70 1.89
1.99 2.07
SC
1.19 1.31 1.44 1.42 1.48
PI
0.71 0.72 0.73 0.74 0.75
46
TC
1.35 1.50 1.68 1.78 1.87
SC
1.08 1.20 1.35 1.32 1.39
PI
0.78 0.79 0.81 0.82 0.82
LEGEND
TC –
Total Cooling Capacity, kW
SC – Sensible
Capacity,
kW
PI –
Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OD –
Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, an A.S.K Kit is required.
Содержание Alpha 12
Страница 30: ...8 1 WIRING DIAGRAMS Revision Y05 01 Service Manual ALPHA 8 WIRING DIAGRAMS 8 1 Indoor Unit Alpha 7 9 12...
Страница 33: ...9 1 ELECTRICAL CONNECTIONS Revision Y05 01 Service Manual ALPHA 9 ELECTRICAL CONNECTIONS 9 1 Alpha 7 9 12...
Страница 82: ...14 12 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y05 01 Service Manual ALPHA 14 12 Outdoor Unit GCN 9 12 RC...
Страница 85: ...14 15 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y05 01 Service Manual ALPHA 14 15 Outdoor Unit GCN 9 12 ST...
Страница 96: ...AIR CONDITIONER SPLIT WALL MOUNTED PROGRAMMING AND OPERATING...