TROUBLESHOOTING 

 

Fault 

Cause 

Solution 

Light on, but 
fan does not 
work 

The  fan  blade  is 
jammed. 

Switch  off  the  unit.  Repair  to  be 
carried  out  by  qualified  service 
personnel only. 

The 

motor 

is 

damaged. 

Both 

light 

and  fan  do 
not work 

Light has blown. 

Replace the lamp with correct rating. 

Power cord loose. 

Plug in to the power supply again. 

Excessive 
Vibration 

The  fan  blade  is 
damaged. 

Switch  off  the  unit.  Repair  to  be 
carried  out  by  qualified  service 
personnel only. 

The fan motor is not 
fixed tightly. 

Switch  off  the  unit.  Repair  to  be 
carried  out  by  qualified  service 
personnel only. 

The unit is not hung 
properly  on  the 
bracket. 

Take  down  the  unit  and  check 
whether  the  bracket  is  in  proper 
location. 

Poor suction 
performance   

Are 

the 

grease 

filters clogged? 

Clean or replace grease filters. 
 

Distance  between 
the  unit  and  the 
cooking  plane  too 
great. 

Adjust the distance to between 70cm 
and 80cm. 

Air flaps Jammed 

Follow the instructions to remove the 
cooker hood, and after disconnecting 
the vent pipe, check the air flaps more 
freely. 

 
 
 

 

 

Содержание eiQ90CANOPYSTEEL

Страница 1: ...AL CANOPY COOKER HOOD eiQ90CANOPYSTEEL Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electriQ co uk fo...

Страница 2: ...S SAFETY 3 UNPACKING AND PRODUCT OVERVIEW 5 OPTIONS FOR VENTILATION 6 INSTALLATION 7 OPERATION 8 FILTER REPLACEMENT 9 BULB REPLACEMENT 10 MAINTENANCE 11 TROUBLESHOOTING 12 TECHNICAL SPECIFICATION 13 S...

Страница 3: ...not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Do not leave fry...

Страница 4: ...lass II construction shall include details that indicate the location and maximum permitted lengths for any fixing or mounting screw or other fixing device that penetrates into the range hood to attac...

Страница 5: ...marked by careless unpacking are not covered under the guarantee Carefully unpack the contents and check everything is there using the table in the next section Product overview parts supplied Packagi...

Страница 6: ...should be made The unit is also provided with an adaptor allowing pre existing 120mm ducting to be used to vent the unit RECIRCULATION This Cooker hood also supports the recirculation of the air once...

Страница 7: ...ood Unit itself where the air outlet vent is located the 2 x flaps should be carefully installed bending very slightly so the lugs at each end locate into the holes enabling flaps to pivot upwards whe...

Страница 8: ...he hood and connect the opposite end of the vent pipe if required OPERATION Your cooker hood is provided with two easy to use slide switches There are 3 speeds for the motor and a separate switch for...

Страница 9: ...uld first be detached Press the lock and pull it downward Put the activated carbon filters into the unit fix them by turning them clockwise onto both sides of the motor housing NOTE Make sure the filt...

Страница 10: ...y 2 Remove the aluminum grease filter 3 Unscrew the panel from the main unit using the 4 screws 4 Follow the wire from the light fitting and disconnect it at the connector with the hood 5 Remove the l...

Страница 11: ...urate the filter Remove the filter as shown in the Installation section Clean it with a soft nylon brush in a mild solution of warm water and a small amount of washing up liquid Washing up liquid alon...

Страница 12: ...carried out by qualified service personnel only The fan motor is not fixed tightly Switch off the unit Repair to be carried out by qualified service personnel only The unit is not hung properly on th...

Страница 13: ...int WBEP 133 1 W Nominal power of the lighting system WL 4 2 W Average illumination of the lighting system on the cooking surface Emiddle 137 lux Measured power consumption on standby mode PS W Measur...

Страница 14: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...

Отзывы: