WATER PLUMBING 

The piping sequence: pool pump / filter / heater / Chlorinator / Pool.  In-line 

chlorinators must be down stream of the heater to minimize harm to the 
pool equipment.  Rigid PVC piping is recommended and all joints should be 

secured with PVC glue.  Make sure that the direction of the water flow 

through the heater is correct as indicated by the labels on the unit.  When 

the piping installation is complete, operate the pool pump and check the 

system for leaks.  Check the filter pressure gauge to ensure that excessive 

pump head pressure is not indicated. 
 

The recommended flow rate is 50 gpm through the heater. 

 

For questions on multiple heater installations, please contact our 

engineering department. Multiple unit installations should always be in 
parallel circuits. 

 

ELECTRICAL HOOK UP 

CAUTION: The main power disconnect must be off before opening the 

access panel.   

 

It is recommended that the wiring of your heater be done by a qualified 

electrician in accordance with local code requirements.   

 
IMPORTANT: The electrical conduit 

must be run up through the base of 

the unit and connected at the control box with a conduit connector. 

 

A properly sized breaker and copper wire must be used.  See inside access 

panel for wiring diagram. 

 

Содержание Swimming Pool Heat Pump

Страница 1: ...Swimming Pool Heat Pump Owner s Installation Operations Manual 5005001B Version 2 02...

Страница 2: ...p 6 Bonding 7 Water Chemistry Maintenance 8 Heat Pump Features 9 Heat Pump Operation 10 Control On Off 10 Pool Spa Modes 10 Changing Set Point Temperature 11 Heater Running Time 11 Keypad Lockout 11 D...

Страница 3: ...c resistance heater does it can heat your swimming pool or spa for up to 80 less cost than these other less efficient methods As with all pool heating methods you are advised to utilize a pool cover a...

Страница 4: ...please take a moment and jot down the following information If you should ever need to call us for service or a question we will need this information Model Number ___________________________________...

Страница 5: ...d through the evaporator coil and discharged through the top grill At least 4 feet clearance should be allowed above the unit for unrestricted air discharge The unit must not be installed under a porc...

Страница 6: ...excessive pump head pressure is not indicated The recommended flow rate is 50 gpm through the heater For questions on multiple heater installations please contact our engineering department Multiple...

Страница 7: ...equipment On some older pools this substructure bond wire may not exist In this case a 6 to 8 ft copper rod must be driven into the ground near the pool equipment and all electrical and metal compone...

Страница 8: ...7 8 1 time per week Chlorine Concentration 1 0 to 3 PPM 1 time every 2 to 3 days Total Alkalinity 80 to 120 PPM 1 time every 2 to 3 weeks Total Dissolved Solids Below 2400 PPM 1 time per month Calcium...

Страница 9: ...abilities ULTRA QUIET The unit is equipped with a low RPM fan motor in combination with a deep drawn venturi to ensure whisper quiet operation HIGH EFFICIENCY The heat pump utilizes the latest in comp...

Страница 10: ...e two settings with the POOL SPA button located on the control When power is applied to the control it will turn on in the previous mode whether it is Pool Heat or Spa Heat When water is flowing throu...

Страница 11: ...When you first run your heater it may need to run continuously for 24 to 48 hours to get the pool up to the desired temperature KEYPAD LOCKOUT While in any mode the user can lockout the keypad by pre...

Страница 12: ...y build up Keep the drain holes in the base free of debris to assure proper condensate drainage Your heat pump s cabinet is made from a maintenance free rust free plastic that is UV resistant It will...

Страница 13: ...TION POSSIBLE CAUSE POSSIBLE SOLUTION Control Display Blank No power supply to heater Tripped breaker or blown fuse Control failure Reset breaker Replace fuse If problem persists call factory for serv...

Страница 14: ...Water sensor malfunction or not connected Call factory for service Pool is heating slowly or not getting up to temperature Low or restricted water flow through the heater Leak in plumbing allowing ai...

Страница 15: ...eed help follow the instructions below Service can be obtained by calling Elecro Engineering Ltd 01438 749474 When asking for help or service please provide a detailed description of the problem your...