W
EATHER
P
ROTECTION
The heater should be installed within a dry weatherproof enclosure.
CAUTION
If the heater is not used during winter months it must be drained to prevent frost damage.
Upon completion of the installation, run the water-circulating pump to purge the system & heater
of air (i.e. remove any trapped air in the system & heater).
The heater must be installed in accordance with the country / regional requirements &
regulations. In any event the work must be carried out by a qualified electrician, who will
provide a certificate of conformity upon completion of the work.
The power supply
must
be fitted with a RCD. If required your electrician may replace the
supplied cable entry gland with a larger one to secure the cable powering the heater, this will not
affect your warranty if carried out by a qualified electrician.
Cable section: should be calculated at 5-amp / mm² for distances up to 20 metres (these sections
are indicative and should be checked and adapted if necessary for cable lengths over 20 metres).
P
OWER
R
EQUIREMENTS
Power Output
Volt (V)
Amp
2-kW
230
9
3-kW
230
13
4.5-kW
230
20
6-kW
230
27
9-kW
230
40
12-kW
230
53
15-kW
230
66
18-kW
230
79
E
LECTRICAL
C
ONNECTION
3 Phase
Power
Output
400V
Star /
230V
Delta
Amp
6-kW
400V / 230V
9 / 15
9-kW
400V / 230V
13 / 23
12-kW
400V / 230V
18 / 31
15-kW
400V / 230V
22 / 38
18-kW
400V / 230V
26 / 46
24-kW
400V
35