Elecro Engineering Cygnet Evolution 2 Скачать руководство пользователя страница 15

15 

 

 

Heater is tripping circuit breaker (MCB) after few minutes/ hours of operation: 

 

If the heater is faulty it will instantly trip the circuit breaker (MCB). The most likely causes of tripping 
the breaker after a period of time are: 

 

Possible Cause 1:  

Faulty circuit breaker. 

Possible Cause 2: 

Incorrect size of the

 

circuit breaker. 

Possible Cause 3:  

Cross section of the cable is not sufficient. 

Possible Cause 4:  

Loose connection(s) of the power supply cable. Check both ends of 
the  power  supply  cable  (at  the  distribution  box  and  at  the  heater 
terminal block). 

 

Remedy: 

Contact an Electrician to check installation and protection. 

 

 

Heater is tripping circuit breaker (MCB) or RCD instantly: 

 

Possible Cause 1:  

Short circuit caused by the wiring or faulty components. 

Possible Cause 2: 

Heating element is going to ground or is damaged. 

Possible Cause 3:  

Moisture inside the heater. 

 

Remedy: 

Send heater back to the manufacturer. Use return form on page 17 
or download it from the Elecro website. 

 

 

Power supply cable is getting very hot: 

 

Possible Cause 1:  

Cross section of the power supply cable is not sufficient. 

Possible Cause 2:  

Loose connection(s) of the power supply cable. Check both ends of 
the  power  supply  cable  (at  the  distribution  box  and  at  the  heater 
terminal block). 

 

Remedy: 

Contact  an  Electrician  to  check  installation.  Inspect  for  loose 
connections and upgrade the power supply cable to a bigger size if 
necessary. 

5.  MAINTENANCE 

 
We recommend annual maintenance and cleaning of the heater to ensure proper operation. 

 

WARNING:

   Before performing any maintenance on the unit isolate from the main power supply. 

 
The  heater  should  be  drained,  the  flow  tube  and  heating  elements  should  be  cleaned.  Removing 
scale/sludge and any debris or blockages will extend life expectancy of the heating element(s) and avoid 
potential failures. 
 
Check that electrical cable connections are properly tightened. 

6. DISPOSAL OF ELECTRICAL/ELECTRONIC EQUIPMENT 

 

DO NOT dispose of this product as an unsorted municipal waste. 

 

This  symbol  on  the  product  or  on  the  packaging  indicates  that  this  product  should  not  be  treated  as 
household waste.  Instead it should be handed over to the applicable collection point for the recycling of 
electrical and electronic equipment. 
 

 

By ensuring this product is disposed of correctly you will help prevent potential 
negative  consequences  for  the  environment  and  human  health,  which  could 
otherwise  be  caused  by  inappropriate  waste  handling  of  this  product.    The 
recycling of materials will help to conserve natural resources. 
 
For  more  information  please  contact  your  local  Civic  Office,  household  waste 
disposal service or the retailer where the product was purchased. 

Содержание Cygnet Evolution 2

Страница 1: ... Cygnet Evolution 2 Pool Heater Digital Installation Operating Manual ...

Страница 2: ...rcuit 8 3 OPERATING INSTRUCTIONS 9 3 1 Flow requirements 9 3 2 Water quality 9 3 3 Selector knob operation 9 3 4 Choose your language 10 3 5 Set point 11 3 6 Heating mode 11 3 7 Calibrate temperature 12 4 TROUBLE SHOOTING 12 5 MAINTENANCE 15 6 DISPOSAL OF ELECTRICAL ELECTRONIC EQUIPMENT 15 7 WARRANTY 16 8 DEDICATED RCD WIRING DIAGRAM FOR CORRECT OPERATION OF THE CYGNET EVOLUTION 2 HEATER 17 9 WIRI...

Страница 3: ...nd To ensure years of trouble free service please read and follow these instructions for proper installation maintenance and use WARNING Failure to install the unit correctly may result in the warranty being void Please retain this manual for future reference 1 PRODUCT OVERVIEW Fig 1 Dimensions for dimension L refer to section 2 5 ...

Страница 4: ...the wall this must cover a minimum of 15cm around the outside of the heater The unit must not be covered to allow adequate ventilation The heater must be installed within a dry permanent weather proof area In any case where water or moisture enters the enclosure the warranty will be void Caution If the heater is unused during the winter months it must be drained to prevent frost damage Water must ...

Страница 5: ...rk The heater should be installed at a low point in the filtration system It should be positioned downstream of after the filter and upstream of before any dosing or other water treatment plan see Fig 3 Fig 3 Fig 4 ...

Страница 6: ...safety loop or kick up in the pipe as close as possible to the heater see Fig 4 NOTE When coupling to a flexible pipe a safety loop can easily be formed by directing the pipe up and over an obstacle Pipe clips should be used to securely fasten all hose connections Fig 6 Fig 7 If rigid pipework is used There is no need to use mastic or PTFE tape to connect unions or hosetails to the heater use the ...

Страница 7: ...d by a qualified Electrician following the instructions provided in this manual The manufacturer will not be liable for any issues caused by poor or improper installation Any alterations made to the unit unless stated will affect the warranty This also applies if components are changed for non standard components acquired anywhere other than direct from the manufacturer Incorrect installation may ...

Страница 8: ...ted RCD Safety Circuit The heater is fitted with a high limit Safety Circuit which must be connected to a dedicated RCD and circuit breaker The Safety Circuit is constantly monitoring the flow tube temperature Air pockets incrustation debris build up or faulty components can be a reason of a sudden temperature rise inside the flow tube To protect heating elements and other components the Safety Ci...

Страница 9: ... of the installation run the water circulating pump to purge the system and heater of air i e remove any trapped air in the system and heater Switch on the power supply to the heater This will be indicated by the illuminated Amber light on the panel Turn the thermostat to the desired temperature The heater will only start heating red light indicator illuminated when the following criteria are met ...

Страница 10: ...he language to English Fig 12 There are five languages to choose from English French Spanish German and Russian To select a language turn the knob clockwise or anti clockwise until the desired language is displayed Press the knob button OK to accept the changes NOTE To access language mode press the knob button during heating only You can also access language mode by resetting power to the heater ...

Страница 11: ... shown on the display see Fig 14 It will appear for two minutes before the device commences the heating process The delay time is required to prevent a cycling effect due to air pockets trapped in the pipe work system or any water fluctuations The combination of the delay time and flow switch sensor is ensuring that the device always receives enough flow and the heating element is fully submerged ...

Страница 12: ...he meter is recording more electricity being used by the heater when the red light is On It is impossible for an electric heater to waste energy if it is drawing power then that power will be turned into heat that will be transferred to the water Accurate Function Test If a more accurate test is required to confirm that your heater is delivering the specified heat output two electricity meter read...

Страница 13: ... could be due to the circulation pump being switched off The pump is not powerful enough to meet the flow requirements See 3 1 Flow requirements The cartridge filter needs cleaning or replacing The sand glass media filter creates too high a back pressure and needs a backwash Fig 17 Possible Cause 3 HEATER DELAY message Please refer to Page 9 Possible Cause 4 OUT OF RANGE message This error message...

Страница 14: ... warm Due to the high efficiency of your electric heater no warmth should be detectable from the flow tube of the heater The most likely causes of the flow tube feeling warm are Possible Cause 1 The heater has been positioned in direct sunlight Possible Cause 2 An air pocket is trapped inside the heater particularly if the tank feels warmer at the highest point of the tank as air rises The water e...

Страница 15: ...heater terminal block Remedy Contact an Electrician to check installation Inspect for loose connections and upgrade the power supply cable to a bigger size if necessary 5 MAINTENANCE We recommend annual maintenance and cleaning of the heater to ensure proper operation WARNING Before performing any maintenance on the unit isolate from the main power supply The heater should be drained the flow tube...

Страница 16: ... Proof of purchase may be required The manufacturer will not be liable in cases of incorrect installation of the heater inappropriate use or neglect of the heater Any damages occurred due to shipping must be reported within 48 hours of receipt of the product Any claims after this time will be considered as misuse or abuse of the product and will not be covered by the warranty Any glass parts seals...

Страница 17: ...17 8 DEDICATED RCD WIRING DIAGRAM FOR CORRECT OPERATION OF THE CYGNET EVOLUTION 2 HEATER ...

Страница 18: ...18 9 WIRING DIAGRAMS ...

Страница 19: ...e Hertfordshire SG1 2BH United Kingdom __________________________________________________________________________________ Customer Information ATTACH TO HEATER Company Name Contact Name Daytime Telephone Number Email Address Return Address Post Zip Code Country Suspect Fault Description of problem ...

Страница 20: ...11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright V01 2019 ...

Отзывы: