15
16
17
18
20
22
23
24
25
19
26
27
14
21
Battery
Groove
Disposing
Examples of attaching gel pad
How to use
After use
Maintenance
How to store
Product specifications
Power button
Concave “Weak” button
Convex “Strong” button
Troubleshooting
Instruction Manual
July 2017 (1st Edition)
ELECOM CO.,LTD.
Eclear Lean
EMS HCT-P01 Series
To care for the gel pad, disconnect it from the main unit.
CAUTION:
Store the gel pad in a place free from direct sunlight, high humidity
and high temperature.
CAUTION:
Check your long used Eclear Lean!
Stopping
use
Loving Check
Have you
notice any
of the
following?
To prevent accidents,
turn off the power or pull
out the dedicated USB
cable and contact the
distributor for a check up.
*1 According to JIS C 8711
*2 With protection function for over-charging, over-discharging and over-voltage
*3 Standard when charging fully discharged battery to full power
*4 Depends on operation and environment
Prevent the water from getting inside the USB connector slot or the main
unit.
A customer who purchases outside Japan should contact the local retailer in the
country of purchase for enquiries. In “ELECOM CO., LTD. (Japan)” , no customer
support is available for enquiries about purchases or usage in/from any countries
other than Japan. Also, no foreign language other than Japanese is available.
Replacements will be made under stipulation of the Elecom warranty, but are not
available from outside of Japan.
WARNING
A lithium ion battery is included in this product. It is a recyclable,
valuable resource, so please recycle. When disposing, follow the
instructions from your local municipal government.
Do not disassemble the battery when disposing.
Do not dispose this product as household waste. The destroyed lithium ion
battery inside a garbage truck causes a short-circuit and may lead to a fire or
heat generation.
The following procedure is for disposing, not for repairing. If you
disassemble this product on your own, the functions will not be
maintained and may cause failures or accidents.
* Attach the gel pad directly to your skin.
CAUTION:
Do not use it on more than two locations at the same time.
How to measure thickness of fat under the skin
Mode
Care of the gel pad
The gel pad needs to be cared for in the following situations:
Gel pad has lost adhesiveness
When stimulation during use has weakened
When stimulation during use feels strengthened
When the gel pad is dirty
When the gel pad is not sticky enough to remain
attached to the storage sheet
Replace the gel pad if you feel there is not enough/too much stimulus during use
even after caring for the gel pad.
How to care for the main unit
When the main unit is dirty, wipe it with a dry soft cloth.
Abnormal sound or vibration
during charging or operation
Main unit becomes extremely
hot
Main unit is deformed or
releases a burning smell
Recycling lithium ion batteries
How to take out a lithium ion battery
Fully discharge the battery.
Disassemble the product in the following manner with
a screw driver.
On the removed battery, place a piece of tape on the
terminals to isolate them, paying attention not to
shirt-circuit the “+” and “-” terminals.
Product name
Eclear Lean
Series model number
HCT-P01
Power source voltage
DC 5.0V ± 5% (Lithium ion battery)
Internal battery
75mAh *1 *2
Number of times charging
can be repeated
Approx. 500 times *1
Charging time
Approx. 2.5 hours *3
Operating time
More than 90 minutes (when fully charged) *4
Rated output voltage
Approx. 42 V
Deep layer frequency
Approx. 2000 to 5000Hz
Relaxation frequency
Approx. 20 to 30Hz
Timer
Approx. 15 minutes
Main unit dimensions
Approx. 48mm × D16mm
Main unit mass
Approx. 20 g
Cable length
Approx. 0.2 m
Operating temperature /
humidity
0°C to 40°C, 20 to 85% RH
Storage temperature /
humidity
-10°C to 60°C, 20 to 85% RH
Made in
China
ELECOM CO., LTD. owns the copyright of this manual.
Copying/reprinting any part, or the whole of this manual without written permission
from ELECOM is prohibited.
The specification or appearance of this product might be changed without prior notice
to improve the product quality.
ELECOM is not responsible for any damages to, or failure of other devices caused by
using this product.
To export the part of this product applicable to strategic goods or services, export or
service trading permission according to foreign currency laws is necessary.
All products and company names on the product and the package are trademarks or
registered trademarks of their respective holders.
©2017 ELECOM Co., Ltd. All Rights Reserved.
MSC-HCT-P01_JP_eng_ver.1
Arm
Abdomen
Buttocks
Half of the thickness
when you pinch the arm
with your elbow bent by
90 degrees
Half of the thickness when
you pinch your abdomen
with it tightened.
Half of the thickness when
you pinch the butt with it
tightened
Your body type
Mode
Thickness of
fat under the
skin (mm)
Overweight
Normal
Thin
A
More than 25 Abdomen, buttocks Abdomen
B
More than 20 Arm, back
Buttocks
Abdomen
C
More than 10 Thigh
Arm, back
Buttocks
D
More than 0 Calf
Calf, thigh
Arm, back, thigh, calf
You can choose your desired strength from fifteen levels.
* The strength level when the main unit is first turned on, or when the
mode is changed, is “1.”
If you press the convex “Strong” button, it beeps and the
strength goes up by 1 level.
If you press the concave “Weak” button, it makes two short
beeping sounds and the strength goes down by 1 level.
If you press the convex “Strong” button at level 15, or the
concave “Weak” button at level 1, it makes three short beeping
sounds and the level stays the same.
Turning the power on
1
Switching mode
Setting the operation sound
4
Turning off
5
Press the power button for two seconds with the gel pad attached to
your skin. The main unit beeps and turns on, and the training starts.
The LED light turns on.
2
Adjusting training level
3
Storing
1
It makes a long beeping sound and the power is turned off
automatically every fifteen minutes after training starts.
* To turn off the power during training, press one of either the power
button, the convex “Strong” button or the concave “Weak” button
for more than two seconds.
* It is also turned off when the gel pad is detached from your skin or
disconnected from the main unit.
Do not disassemble this product unless you are disposing of it.
Rectus abdominis / core pad
Abdominal oblique / twin pad
Adductor muscles / twin pad
Quadriceps femoris / core pad
Tibialis anterior / twin pad
Triceps brachii / twin pad
Latissimus dorsi / core pad
Gluteus maximus / core pad
Biceps femoris / core pad
Triceps surae / twin pad
Gluteus medius / core pad
Core pad
Twin pad
Core pad
Twin pad
Front
Back
You can switch between the modes by pressing the power button
during operation.
* The operation always starts in mode A.
It beeps every time you press the power button and the mode
changes. It makes a long beep sound when it goes back to mode A.
You can turn on/off the operation sound.
Press the concave “Weak” button and the power button at the
same time for one second. It makes one short and one long
beeping sound and the operation sound is turned off.
Press the convex “Strong” button and the power button at the
same time for one second. It makes one short and one long
beeping sound and the operation sound is turned on.
* The operation sound is not turned off for some operations for the
safety reasons. Please note that it is by design, not a malfunction.
* If you turn off the operation sound by mistake, press the convex
“Strong” button and the power button simultaneously.
Make sure the power is turned
off and peel off the gel pad from
your skin.
Pinch the grip of the gel pad and
peel it off being careful not to
touch the adhesive surface.
Do not disconnect the gel pad from the main unit and attach it to
the storage sheet.
* For the paired gel pad, attach one core pad on one side of the storage
sheet and attach two twin pads
on the other side.
Store it in the enclosed storage
bag.
Run a small amount of water on the surface and rub it gently with your
fingertips for several seconds.
* Do not pour too much water. It will cause loss of adhesive strength or
damage to the
adhesive surface.
Hold it by the grip and shake it enough to remove
the excess water and let it air dry.
* If it is not completely dry, it loses adhesive strength.
* Never wipe the adhesive surface with tissue paper or
a cloth.
* Avoid direct sunlight.
Store this product in an environment meeting the following conditions:
Storage temperature: -10ºC to 60ºC
Storage humidity: 20 to 85% RHºC
Caution when Maintaining and Storing
Do not use benzine or paint thinner when caring for the
product.
Do not store this product in any of the following places:
– A place with direct sunlight
– A place exposed to high temperature,
high humidity, water or excess dust
– A place with high vibration
– A place where chemicals are stored or an environment with corrosive gas
Keep this product away from children.
If you are not using it for a long period of time, store at room temperature (10
to 30ºC) in its fully charged condition.
Charge it at least once in three months. If it is completely discharged,
recharging might be impossible.
Open the cover by inserting a minus screw
driver into the groove right below the power
button on the main unit.connector slot of
the main unit.
Unscrew the screw fastening the base plate.
Cut off the power cord using a nipper from
the black cord on the back of the base plate.
Remove the battery.
This product has 4 modes. There are suitable training modes and attachment
methods for the respective body parts and thickness of the fat layer.
Grip
Storage
sheet
Benzine
Paint
thinner
Nail polish
remover
Alcohol
Beeping sound ON
Beeping sound OFF
Convex
“Strong” button
Concave
“Weak” button
Power button
Power button
Press them together for
one second or more
Press them together for
one second or more
Trouble
Does not turn on
Battery is not charged fully or there is no power left in battery
Turn off the power and charge the battery.
P.11
During charging
Pull out the dedicated USB cable after charging is completed.
P.11
Gel pad is not attached to skin
Turn on the power after attaching the gel pad to your skin correctly.
P.13
Gel pad adhesive surface peels off
or slides out of position
Excess amount of sweat or water on adhesive surface of gel pad
The gel pad is a consumable. Stop using it when the adhesive surface is damaged and purchase another gel pad.
P.9
No sound
Muted by mistake
Muting can be canceled by pressing both of the “Strong” button and the power button simultaneously.
P.15
Power goes off immediately
after being turned on
Power goes off during use
Battery is not charged fully or there is no power left in battery
Turn off the power and charge the battery.
P.11
Main unit and gel pad are not connected correctly to each other
Turn off the power and reconnect the main unit and the gel pad.
P.12
· P.13·
Gel pad is not attached to skin correctly
Turn off the power then attach the gel pad to your skin correctly.
P.13
Cannot charge the battery
Battery has discharged after a long period of storage
Cannot be used. Charge every three months to prevent it from being discharged completely.
P.21
Cause
How to troubleshoot
Gel pad does not stay
on the skin
Transparent protective film is not removed from the adhesive surface of the gel pad
Remove the transparent protective film from the adhesive surface of the gel pad.
P.13
Adhesive surface of the gel pad is dirty
Run a small amount of water on the surface and rub it with your fingertips for several seconds.
P.20
Using immediately after rinsing with water
Shake off the excess water and air dry the adhesive surface.
P.20
Adhesive surface of the gel pad is damaged
The gel pad is a consumable. Stop using it when the adhesive surface is damaged and purchase another gel pad.
P.9
Skin becomes red /
skin feels prickly
Used for too long
Limit the workout time on one location up to 30 minutes and peel off the gel pad after use.
P.15
Gel pad is not attached to skin firmly
Attach the gel pad to your skin firmly.
P.13
Adhesive surface of the gel pad is dirty or dry
Run a small amount of water on the surface and rub it with your fingertips for several seconds.
P.20
Adhesive surface of the gel pad is damaged
The gel pad is a consumable. Stop using it when the adhesive surface is damaged and purchase another gel pad.
P.9
No / weak stimulus felt
Gel pad is not attached to skin firmly
Attach the gel pad to your skin firmly.
P.13
Gel pad is overlapping with another gel pad
Attach it being careful not to overlap with another gel pad.
P.13
Adhesive surface of the gel pad is dirty
Run a small amount of water on the surface and rub it with your fingertips for several seconds.
P.20
Gel pad is not connected correctly
Connect it correctly by pushing in until it clicks.
P.12
Level is set to “Weak”
Adjust the level.
P.15
It is not charged enough or the battery is out of power
Charge the battery.
P.11
Adhesive surface of the gel pad is dirty or damaged
The gel pad is a consumable. Stop using it when the adhesive surface is damaged and purchase another gel pad.
P.9