E-ink 14 segment display

The battery status is indicated by a 14 segment Eink display.

The battery is fully charged when the 14 Eink segments are 
black, and as the battery discharges the segments turn white.

The battery is completely discharged when all 14 Eink 
segments are white.

Discharge

Charge

Time to charge may vary depending on the chargers being 
used and temperature, among other variables. 

The evo2 batteries can be charged with the supplied charger 
or with compatible chargers.

Rated voltage of the charger should not exceed 12.6 V

Recommended standard charge 1.2 A Maximum current 
permitted 3.2 A

Continuous discharge 640mA/0.2C, relative capacity at 
25oC~ 100%

Maximum continuous discharge 6.4A/2C, relative capacity at 
25oC~ 95% 

Maximum discharge peak 9.4A

The battery display turns white after total discharge of battery.

Warranty of the evo2 battery

6 month warranty.

Caution 

Never short circuit the terminals.

Do not expose the battery to heat or a fire source.

The battery should always be kept clean and dry, away from 
water or wet environments.

Do not manipulate the battery. In case of manipulation, the 
warranty is no longer valid.

For long term storage, the battery should be charged to 50% 
of its capacity, and recharged every 3 months.

Check the charge status every 3 months and recharge. Do not 
store the battery discharged, as it might cause irreversible 
damages.

Do not use the battery if there are any impacts, dents, etc.

If for any reason a battery loses its charge and remains 
uncharged for a long period of time, make sure to check the 
battery before charging. Voltage between terminals must be 
more than 7.5 V. If the voltage is under this value, do not 
attempt to charge the battery and proceed to send it to our 
technical service. 

!

Use chargers recommended by the manufacturer to
charge the batteries.