4. EWS2 ZONE, PGM OUTPUT & TAMPER

Upon successful EWS2 outdoor siren binding process,the system adds 1 wireless 

Instant

 zone and 1 wireless 

Siren

 PGM output. The wireless 

zone is intended for EWS2 tamper control and the wireless PGM output is for siren control.
In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper violation 

on EWS2:

•  

By tamper button.

 EWS2 has a built-in tamper button intended for monitoring the enclosure status. Once the enclosure of EWS2 

is illegally opened, the tamper button becomes unpressed. This action is followed by alarm which is sent by SMS message and phone 

call to the user (-s) by default. The SMS message contains the violated tamper number.

•  

By wireless connection loss. 

The wireless connection loss between EWS2 and ELDES alarm system leads to alarm. The system 

identifies this event as a tamper violation and sends alarm by SMS message and phone call to the user (-s) by default. The SMS mes-

sage contains the violated tamper number and a star * character indicating wireless connection loss as a tamper alarm cause.

ATTENTION: 

 The tamper will not operate if the wireless zone is disabled.

5. BATTERY REPLACEMENT

1.   Open EWS2 enclosure.
2.   Remove all 4 old batteries from the battery slots.
3.   Position the 4 new 1,5V alkaline AA type batteries according to the appropriate battery slot positive/negative terminals indicated on the 

PCB (printed-circuit-board) of EWS2.

4.   Batteries replaced.

See chapter 

3.   INSTALLATION

 for more details.

ATTENTION: 

 Only 1,5V Alkaline AA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old 

batteries with the new ones.

ATTENTION: 

 At least 1 battery must be removed if the device is not in use.

ATTENTION: 

 In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken 

when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, disas-

semble, heat or incinerate old batteries. 

NOTE: 

 The system sends an SMS message to a preset User 1 as soon as the battery level runs below 5%.

NOTE: 

 The battery status can be monitored in real-time using ELDES Configuration Tool software. 

Содержание EWS2

Страница 1: ...EWS2 OUTDOOR WIRELESS SIREN...

Страница 2: ...ators and operates with ELDES wireless alarm systems EWS2 has to be bind to the alarm system by sending a corresponding SMS message or using software ELDES Configuration Tool Upon successful EWS2 bind...

Страница 3: ...n Range Up to 30 meters 98 43ft in premises up to 150 meters 492 13ft in open areas Compatible with Alarm Systems ELDES Wireless This operation time might vary in difference conditions Depends on firm...

Страница 4: ...de of the enclosure by pulling the lid up see Fig No 2 2 Unscrew the front side of the enclosure see Fig No 3 3 Detach the front side of the enclosure by pulling the front side up see Fig No 4 4 2 Onc...

Страница 5: ...on The device can also be paired by sending a corresponding command via SMS text message For more details please refer to the software s HELP section and ELDES alarm system user installation manual 7...

Страница 6: ...ed tamper number and a star character indicating wireless connection loss as a tamper alarm cause ATTENTION The tamper will not operate if the wireless zone is disabled 5 BATTERY REPLACEMENT 1 Open EW...

Страница 7: ...service Manufacturer Warranty This device carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been pur chased by the end user The warranty is v...

Страница 8: ...MadeintheEuropeanUnion www eldes lt...

Отзывы: