66
EN
USER MANUAL EWS2 V2.2
4. EWS2 ZONE, PGM OUTPUT & TAMPER
Upon successful EWS2 outdoor siren binding process,the system adds 1 wireless
Instant
zone and 1 wireless
Siren
PGM output. The wireless
zone is intended for EWS2 tamper control and the wireless PGM output is for siren control.
In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper violation
on EWS2:
•
By tamper button.
EWS2 has a built-in tamper button intended for monitoring the enclosure status. Once the enclosure of EWS2
is illegally opened, the tamper button becomes unpressed. This action is followed by alarm which is sent by SMS message and phone
call to the user (-s) by default. The SMS message contains the violated tamper number.
•
By wireless connection loss.
The wireless connection loss between EWS2 and ELDES alarm system leads to alarm. The system
identifies this event as a tamper violation and sends alarm by SMS message and phone call to the user (-s) by default. The SMS mes-
sage contains the violated tamper number and a star * character indicating wireless connection loss as a tamper alarm cause.
ATTENTION:
The tamper will not operate if the wireless zone is disabled.
5. BATTERY REPLACEMENT
1. Open EWS2 enclosure.
2. Remove all 4 old batteries from the battery slots.
3. Position the 4 new 1,5V alkaline AA type batteries according to the appropriate battery slot positive/negative terminals indicated on the
PCB (printed-circuit-board) of EWS2.
4. Batteries replaced.
See chapter
3. INSTALLATION
for more details.
ATTENTION:
Only 1,5V Alkaline AA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old
batteries with the new ones.
ATTENTION:
At least 1 battery must be removed if the device is not in use.
ATTENTION:
In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken
when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, disas-
semble, heat or incinerate old batteries.
NOTE:
The system sends an SMS message to a preset User 1 as soon as the battery level runs below 5%.
NOTE:
The battery status can be monitored in real-time using ELDES Configuration Tool software.
Содержание EWS2
Страница 1: ...EWS2 OUTDOOR WIRELESS SIREN...
Страница 8: ...MadeintheEuropeanUnion www eldes lt...