Disable EPGM8 mode
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PGM OUTPUTS
→
OK
→
USING EPGM8
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 33 and parameter status value:
33 0 #
Example:
330#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
18.3. PGM Output Names
Each PGM output has a name that can be customized by the user. Typically, the name specifies a device type connected to a determined
PGM output, e.g. Lights. The name can be used instead of PGM output number when controlling the PGM output by SMS text message. By
default, the PGM output names are:
C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Controll4 etc.
Set PGM output name
SMS
SMS text message content:
ssss_Coo:out-name
Value:
ssss
– 4-digit SMS password;
oo
– PGM output number, range – [1... 44];
out-name
–
up to 16 characters PGM output name.
Example:
1111_C2:Lights
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View PGM output
names
SMS
SMS text message content:
ssss_STATUS
Value:
ssss
– 4-digit SMS password.
Example:
1111_STATUS
EKB2
Menu path:
On-board PGM output:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PGM OUTPUTS
→
OK
→
ONBOARD OUTPUTS
→
OK
→
OUTPUT 1... 12
→
OK
→
NAME
Value:
aaaa
– 4-digit administrator password.
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
ATTENTION:
Space, colon, semi-colon characters, parameter names and/or values, such as PSW, STATUS, ON, OFF etc. are NOT allowed in
PGM output names.
18.4. Turning PGM Outputs ON and OFF
By default, all PGM outputs are turned OFF. To instantly turn ON/OFF an individual PGM output and set its state to ON/OFF when the system
starts-up, please refer to the following configuration methods.
Turn ON PGM output/
Set PGM output start-
up state as ON
SMS
SMS text message content:
ssss_Coo:ON
or
ssss_out-name:ON
Value:
ssss
– 4-digit SMS password;
oo
– PGM output number, range – [1... 44];
out-name
–
up to 16 characters PGM output name.
Example:
1111_Lights:ON
EKB2
Menu path:
On-board PGM output:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PGM OUTPUTS
→
OK
→
ONBOARD OUTPUTS
→
OK
→
OUTPUT 1... 12
→
OK
→
STATUS
→
OK
→
ENABLED
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number and parameter status value:
61 oo 1 #
Value:
oo
– PGM output number, range – [01... 44].
Example:
61031#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Turn OFF PGM output/
Set PGM output start-
up state as OFF
SMS
SMS text message content:
ssss_Coo:OFF
or
ssss_out-name:OFF
Value:
ssss
– 4-digit SMS password;
oo
– PGM output number, range – [1... 76];
out-name
–
up to 16 characters PGM output name.
Example:
1111_C2:OFF
EKB2
Menu path
:
On-board PGM output:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
PGM OUTPUTS
→
OK
→
ONBOARD OUTPUTS
→
OK
→
OUTPUT 1... 12
→
OK
→
STATUS
→
OK
→
DISABLED
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number and parameter status value:
61 oo 0 #
Value:
oo
– PGM output number, range – [01... 44].
Example:
61020#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
To instantly turn ON an individual PGM output for a determined time period and automatically turn it OFF when the time period expires,
please refer to the following configuration method.
Turn ON PGM output
for time period
SMS
SMS text message content:
ssss_Coo:ON:hr.mm.sc
or
ssss_out-name:ON:hr.mn.sc
Value:
ssss
– 4-digit SMS password;
oo
– PGM output number, range – [1... 44];
out-name
– up to 16 characters PGM output name;
hr
– hours, range – [00... 23];
mn
– minutes, range
– [00... 59];
sc
– seconds, range – [00... 59].
Example:
1111_C4:ON:10.15.35
To instantly turn OFF an individual PGM output for a determined time period and automatically turn it ON when the time period expires,
please refer to the following configuration method.
Turn OFF PGM output
for time period
SMS
SMS text message content:
ssss_Coo:OFF:00.00.sc
or
ssss_out-name:OFF:hr.mn.sc
Value:
ssss
– 4-digit SMS password;
oo
– PGM output number, range – [1... 44];
out-name
– up to 16 characters PGM output name;
hr
– hours, range – [00... 23];
mn
– minutes, range
– [00... 59];
sc
– seconds, range – [00... 59].
Example:
1111_Lights:OFF:00.00.23
When the PGM output is turned ON or OFF, the system will send a confirmation by SMS text message to the user phone number that the
SMS text message was sent from.
NOTE FOR EKB2/EKB3/CONFIG TOOL USERS:
Only the startup state of the PGM output can be changed using these configuration
methods
NOTE:
PGM output can be turned ON for a determined time period only when it is in OFF state
NOTE:
PGM output can be turned OFF for a determined time period only when it is in ON state
NOTE:
Multiple PGM outputs can be turned ON/OFF by a single SMS text message,
Example:
1111_C1:ON C2:OFF Pump:ON C4:ON:00.20.25