Seq. No.  Event 

Description 

8

Mains Power 

Restore

SMS text message sent to the user in case the mains power 

supply is restored. For more details on how to manage this 

notification, please refer to 

12. BACK-UP BATTERY AND 

MAINS POWER SUPPLY STATUS MONITORING.

9

Battery Connected SMS text message sent to the user in case the battery level 

reaches the back-up battery is connected. For more details 

on how to manage this notification, please refer to 

12. 

BACK-UP BATTERY AND MAINS POWER SUPPLY STATUS 

MONITORING.

10

Battery Discon-

nected

SMS text message sent to the user in case the battery level 

reaches the back-up battery is disconnected. For more 

details on how to manage this notification, please refer to 

12. 

BACK-UP BATTERY AND MAINS POWER SUPPLY STATUS 

MONITORING.

11

Low Battery 

SMS text message sent to the user in case the battery level 

reaches the set up minimum value. For more details on how to 

manage this notification, please refer to

 12. BACK-UP BAT-

TERY AND MAINS POWER SUPPLY STATUS MONITORING.

12

Device Shutdown

When the system is running on backup battery power, it sends 

the SMS text message when backup battery voltage reaches 

7.8V - before it is fully depleted. For more details on how to 

manage this notification, please refer to the configuraition 

methods below.

13

Temperature Info 

SMS text message sent to the user in case the temperature 

measured by external temperature sensor drops below the 

MIN or rises above the MAX value. For more details on how to 

manage this notification, please refer to 

8.2.2. Temperature 

Sensor Mode. 

14

Internal Temper-

ature

SMS text message sent to the user in case the temperature 

measured by built-in temperature sensor drops below the 

MIN or rises above the MAX value. For more details on how 

to manage this notification, please refer to 

15. ON-BOARD 

TEMPERATURE SENSOR. 

Содержание ESIM022

Страница 1: ...ESIM022 GSM DIALLER...

Страница 2: ...s places External power supply must be reachable and can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of discon necting circuit in the event of...

Страница 3: ...c Equipment marking on this product see right or its documentation indicates that the product must not be disposed of to gether with household waste To prevent possible harm to human health and or the...

Страница 4: ...outlined in this manual and in accordance with the operating conditions specified The warranty is void if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and...

Страница 5: ...ration of an electronic device by SMS text message or phone call Main features Configuration by SMS text message and PC Up to 2 users for system configuration control and acceptance of system event no...

Страница 6: ...collector output Output is pulled to COM when turned ON Maximum commuting output values 30 V 200 mA Number of inputs 2 Supported temperature sensor model Maxim Dallas DS18S20 DS18B20 PCB dimensions 71...

Страница 7: ...ector Backup battery slots F1 0 5A fuse LED indication Description OFF No power supply Flashing every 30 ms SIM card is not present PIN code enabled Flashing every 0 5 sec Searching for GSM network Fl...

Страница 8: ...ensor wiring ESIM022 Alarm system or other appliance 12V PGM2 PGM1 Z1 Z2 COM COM DC C1 ESIM022 DS18S20 DS18B20 Temperature sensor COM Z1 Z2 DC C1 COM GND GND DATA DATA 4V 4V Output wiring ESIM022 Alar...

Страница 9: ...oser than 20 cm to the metal surface and or power lines 3 Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps 4 Once the PIN code is di...

Страница 10: ...ices that might cause incorrect sys tem operation Please contact your GSM operator for more details on these services and how to disable them NOTE For maximum system reliability we recommend you do NO...

Страница 11: ...o ne call regarding system alarm restore arming disarming and other events depending on alarm system configuration In addition to being informed by SMS text message or phone call regarding alarm and r...

Страница 12: ...al computer in the process Before starting to use EL DES Configuration Tool software please read the user guide provided in the soft ware s HELP section ELDES Configuration Tool is freeware and can be...

Страница 13: ...ber of the system for the first time the system will reject the phone call and au tomatically set up the phone number as User 1 phone number that the phone call has been made from This feature DOES NO...

Страница 14: ...S SMS text message content CLK yyyy mm dd_hr mn Value yyyy year mm month range 01 12 dd day range 01 31 hr hours range 00 23 mn minutes range 00 59 Example CLK 2013 03 16_14 33 Config Tool This operat...

Страница 15: ...or input Z1 a Monitors input voltage ranging from 0 mV through 3000 mV every 100 millisecond b Verifies if the set up threshold by default 1500 mV is not exceeded c By default the input is set as NO n...

Страница 16: ...ls on how to manage the alarm restore notifications please refer to 10 ALARM RESTORE NOTIFICATIONS For more details on how to view system s information that may include input state please refer to 13...

Страница 17: ...from the PC using the ELDES Configuration Tool software 8 2 1 Digital Mode When Digital mode is set the system follows this pattern a Monitors input voltage ranging from 0 mV through 3000 mV every 100...

Страница 18: ...may be carried out from the PC using the ELDES Configuration Tool software Set input as NO normally open SMS SMS text message content ZONE2 NO Example ZONE2 NO Config Tool This operation may be carrie...

Страница 19: ...ry 60 minutes To set a different temperature update period please refer to the following configuration methods Set temperature update period SMS SMS text message content PTEMP temp per Value temp per...

Страница 20: ...may be carried out from the PC using the ELDES Configuration Tool software Temperature Info SMS The system supports an SMS text message identified as the Temperature Info SMS which is auto matically...

Страница 21: ...d MAX thresholds Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View temperature sensor name and temperature value SMS SMS text message content S...

Страница 22: ...refer to 14 SYSTEM NOTIFICATIONS 9 TAMPER The system comes equipped with on board tamper switch designed for sabotage detection In the event of enclosure tampering the system can notify the user by S...

Страница 23: ...DES Configuration Tool software SMS By default in the event of tamper or input alarm or restore the system will follow this pattern a The system attempts to send an SMS text message containing input a...

Страница 24: ...Zi ON Value i input number range 1 2 Example SAZ2 ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Set input alarm text SMS SMS text message con...

Страница 25: ...re text up to 23 characters input restore text Example TRZ1 Restore Z1 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disable tamper alarm restor...

Страница 26: ...ng the first preset user phone number b When the call is answered the user will be able to listen on the mobile phone for 60 seconds to what is happening in the area surrounding the system see 16 REMO...

Страница 27: ...input alarm SMS SMS text message content CAZi OFF Value i input number range 1 2 Example CAZ2 OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software...

Страница 28: ...Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software ATTENTION Inputalarm restorenotificationsdoNOTapplywheninputZ2issetuptooperatein Temperature Senso...

Страница 29: ...to wire the output please refer to 2 3 Wiring Diagrams 11 1 Output Name The output has a name that can be customized by the user Typically the name specifies a device type connected to the output for...

Страница 30: ...software Turn OFF output SMS SMS text message content OUT OFF Example OUT OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View output status...

Страница 31: ...is 8V or lower By default the notifications regarding the back up battery status are disabled To enable disable a certain notification please refer to the following configuration methods Enable Batte...

Страница 32: ...onfiguration Tool software Disable Battery Disconnected notification SMS SMS text message content BATDIS OFF Example BATDIS OFF Config Tool This operation may be carried out from the PC using the ELDE...

Страница 33: ...ault system notification by SMS text message regarding mains power supply status is disa ble To enable disable a certain notification please refer to the following configuration methods Enable Mains P...

Страница 34: ...ext Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disable Mains Power Supply Restore notification SMS SMS text message content PWRREST OFF Examp...

Страница 35: ...be carried out from the PC using the ELDES Configuration Tool software By default the aforementioned items except System name are excluded from the Status SMS To include them please refer to the follo...

Страница 36: ...periodic Status SMS and set frequency SMS SMS text message content TEST frequen Value frequen frequency range 1 1193046 hours Example TEST 15550 Config Tool This operation may be carried out from the...

Страница 37: ...s on how to manage this notification please refer to the configuraition methods below 2 Input Alarm SMS text message sent to the user in case input Z1 or Z2 is violated For more details on how to mana...

Страница 38: ...essage sent to the user in case the battery level reaches the set up minimum value For more details on how to manage this notification please refer to 12 BACK UP BAT TERY AND MAINS POWER SUPPLY STATUS...

Страница 39: ...Disable Device Started notification SMS SMS text message content SSMS OFF Example SSMS OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software By def...

Страница 40: ...guration Tool software View system notification parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software ATTENTION Colon dash commacharactersare...

Страница 41: ...re SMS to the preset user phone number To enable disable the on board temperature sensor as well as to set and view the MIN MAX tem perature thresholds please refer to the following configuration meth...

Страница 42: ...will last for up to 60 seconds until the system automatically hangs up By default when the preset user dials the system phone number the system automatically an swers the call This feature is identif...

Страница 43: ...Value mg microphone gain range 1 15 Example MIC 10 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View remote listening parameters Config Tool Th...

Страница 44: ...redit balance No GSM network signal Wrong user phone number User phone number is not set Received SMS text message Wrong syntax Incorrect SMS text message structure Unnecessary space character might h...

Страница 45: ...le to the PC 4 The new window must pop up where you will find the bin file Otherwise open My Computer and look for CRP DISABLED drive 5 Delete the bin file found in the drive 6 Copy the new firmware b...

Страница 46: ...46 46 EN ESIM022 User manual v1 0 18 RELATED PRODUCTS DC power supply DS18S20 temperature sensor Microphone...

Страница 47: ...47 47 ESIM022 User manual v1 0...

Страница 48: ...MadeintheEuropeanUnion www eldes lt...

Отзывы: