Eldes EKB1 Скачать руководство пользователя страница 5

1.4 Connector and LED Indicator Functionality

Fig. No. 1

LEDs

STAY

STAY (perimeter security) state indicator

ARMED

ARMED (armed security) status indicator

BYPASS

BYPASS (temporary zone disconnection) status indicator

Connector Functionality

+12V

Positive supply pin +12-14 VDC connected to the main unit AUX 

DATA

Data pin connected to the main unit DATA

GND

Negative supply pin connected to the main unit GND (COM)

1.5 Keyboard installation and configuration

1. Fix the keyboard holder to the wall.
2.   Disconnect   security   system   ESIM262   power   supply   and   backup   battery   before 
connecting wires.
3. Connect keyboard connectors to ESIM262. Accordingly, +12 V must be connected 
to AUX, DATA – to DATA, GND – to GND.  
4. Infix the keyboard into the holder.
5. Turn on ESIM262 power supply.

ESC and ENT must be constantly lit.

If   not   all   security   zones   are   used,   it   is   necessary   to   use   resistors   with   the   unused   zones. 
Otherwise a red  BYPASS indicator will light up, even if a particular zone is turned off by SMS 
message or using configuration tool.

User manual EKB1 v1.0                                      

5

Note

If DALLAS key reader and/or temperature sensor are connected to ESIM262, DATA connector 
used is the same. I. e., all components containing DATA output must be connected in parallel.

Содержание EKB1

Страница 1: ...Keyboard EKB1 User Manual v1 0...

Страница 2: ...ranty period starts from the day the system has been purchased by the end user The war ranty is valid only if the system has been used as intended following all guidelines listed in the manual and wit...

Страница 3: ...keyboard EKB1 and its connection to security and alarm system ESIM262 It is very important to read User Manual before start using the system Content 1 1 Function 6 1 2 Operation Description 6 1 3 Tec...

Страница 4: ...ot open the door or in other words Z1 is not triggered after entering the code the alarm will turn to STAY mode when only the marked zones are secured The user is notified about this by the yellow LED...

Страница 5: ...system ESIM262 power supply and backup battery before connecting wires 3 Connect keyboard connectors to ESIM262 Accordingly 12 V must be connected to AUX DATA to DATA GND to GND 4 Infix the keyboard...

Страница 6: ...one_NO ENT E g to disconnect zone 5 press ESC 5 ENT Red LED indicator will light up immediately To turn off BYPASS mode enter analogous command sequence ESC 5 ENT The indicator will switch off Turning...

Страница 7: ...making the changes exit the mode The user will be informed about every successful command by a sound signal beeping several times In the case of failure or error it will beep once Description Command...

Страница 8: ...Made in Lithuania www eldes lt User manual EKB1 v1 0 8...

Отзывы: